Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

124 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
Location of the STBY LED, F/W LED and BMC LED
Running Diagnostic Software Tools
This section includes information on the following diagnostic tools:
HP e-DiagTools Hardware Diagnostics
LED Description
1 STBY This standby LED comes on as soon as the server power cord is plugged in. If this light
is off when you plug it in, reseat the power supply. If this does not work, replace the
power supply.
2 BMC A few seconds after the server is plugged in this LED starts blinking, which means that
the Baseboard Management Controller is alive. If this LED is not blinking and the STBY
(standby) LED is on, you may have to replace the system board.
3 F/W A few seconds after the power button is pressed in the system firmware code fetch LED
comes on indicating that the firmware has started the boot process. If this LED does
not come on, you may have to replace the system board.
3
2
1
1
2, 3