130 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Troubleshooting
28 Memory errors detected and PDT is
disabled
Reseat DIMMs, if error persists
replace bad DIMMs
30 Memory required reinterleave to get a
good page 0
—
31 One or more ranks have chipspare
disabled
—
33 One or more memory ranks are
mismatched and deallocated
Fix memory loading order.
34 Memory deallocated because of a loading
error
Fix memory loading order.
35 Memory is not loaded recommended
loading order
Fix memory loading order.
36 The PDT is full Clear with pdt clear command in
EFI shell
37 At least one (1) CPU has bad fixed core
ratio
—
38 All CPUs were slated for compatibility
deconfig
—
39 Incompatible CPUs detected Call support center
40 CPUs installed with mixed cache sizes This will always cause a stopboot
41 CPUs installed with mixed steppings —
42 All CPUs are over clocked —
43 At least one (1) CPU is over clocked —
44 Monarch changed to lowest stepping CPU Only seen once after monarch is
set to lowest stepping
46 CPUs loaded in wrong order —
48 SAL NVM cleared Information only, no action
required
49 EFI NVM cleared Information only, no action
required
50 EFI NVM failed —
51 CPU deconfigured by SAL_B —
52 A ROM revision is inconsistent with FIT or
REVBLOCK
One or more firmware components
(fw, bmc, mp) is out of date.
Update Firmware.
53 Error building SMBIOS Call Support Center
Error Number Error/Warning Message Solution