Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 131
Troubleshooting
SEL and FPL Log Entries
This section is a quick reference for the IPMI events recorded in the SEL and FPL files. These
logs are available using the iLO MP card interface or the BMC CLI.
All entries from the SEL are forwarded to the FPL. The FPL is a circular log so the newest
entries replace the oldest. The FPL contains forward progress messages from the BMC,
System firmware, EFI, and the OS.
The SEL does not accept new entries once it is full and contains only those events considered
of major importance to system operation.
Both contain type 02 and E0 messages.
A triplet is formed from the SensorType, EventType, and the lower nibble of the Data1
fields of Type 02 events. iLO MP firmware displays the triplet in the Keyword field.
NOTE: Servers with firmware version 2.0 or higher also have a clearlogs command that clears
out the log files should they become full.
Accessing the Logs with BMC CLI Commands
The fpl command displays the forward progress log. For example:
1 2 3 4 5 6 7
0000000E - Pwr Spply 1 Ctrl Enabled 44-08:09:01 2003-02-28 16:41:46
0000000F 2 CPU0 Boot start 00063 DT 06 0000000000000000
00000010 2 CPU0 Boot start 00063 Time 2003-02-28 16:41:46
00000011 0 CPU0 00020 DT 00 0000000000000000
00000012 0 CPU0 0000E DT 06 0000000000010000
00000013 1 CPU0 CPU monarch 0000C DT 06 0000000000000000
00000014 1 CPU0 CPU present 00261 DT 06 0000000000000000
00000015 0 CPU0 00008 DT 00 0000000000000000
00000016 0 CPU0 0024B DT 00 0000000000000000
00000017 0 CPU0 00006 DT 03 0000000000000000
00000018 0 CPU0 00044 DT 06 02000000002C0400
00000019- BMC LPC reset 00-12:70:02 2003-02-28 16:41:47
54 Failure constructing the EFI Memory Data
Table (MDT)
Call Support Center
55 UUID error Call Support Center
56 Error reading CPU SMBUS information
ROM
57 Error accessing FRU information
58 Checksum error accessing FRU information
59 FRU information version error
Error Number Error/Warning Message Solution