Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 133
Troubleshooting
Log Entry 15: 28 Feb 2003 16:41:47
Alert Level 2: Informational
Keyword: Type-02 127002 1208322
Soft Reset
Logged by: BMC; Sensor: System Event
0x203E5F914B020110 FFFF027000120300
Keyword mode example:
13 BMC 2 0x203E5F914A0200E0 FFFF010944080300 Type-02 080901 526593
28 Feb 2003 16:41:46
14 SFW 0 2 0x5680006300E000F0 0000000000000000 BOOT_START
28 Feb 2003 16:41:46
15 BMC 2 0x203E5F914B020110 FFFF027000120300 Type-02 127002 1208322
28 Feb 2003 16:41:47
System Specific Events
OEM SensorType 12, EventType 71
Missing components are determined at the time of a power-on request. They cause a failure in the
request and cause the event to be logged.
Chassis Control Event Codes
For BMC rev 1.41+, an SEL event is logged for each ChassisControl event, whether it’s
generated by an IPMI request, or a sensor event.
Later revisions of iLO MP firmware recognize the triplet (12:70:A3) as Chassis Control.
The EventData fields are as follows:
Data1: 0xA3 (indicating OEM data in Data2 and Data3, and OEM offset 3)
Data2:
[7] 0 = Request generated by a Sensor Event
1 = IPMI request
[6-4] Reserved
[3-0] ChassisControl command
Data3: Sensor Number or IPMI Request Origin
Data2 Data3 Missing Component
0x0C-0F Power Pod 0-3
0x20-23 CPU 0-3
0x1E 0x01 Cooling Unit 1
0x1E 0x01 Cooling Unit 3
0x1E 0x03 Cooling Unit 3