Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 135
Troubleshooting
Data2 Data3
80 03 ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_DOWN (“p 0”)
81 03 ipmi req from the CLI thd for CHASSIS_CONTROL_POWER_UP (“p 1”)
80 01 ipmi req from via BT for CHASSIS_CONTROL_POWER_DOWN
83 03 ipmi/RS req from the CLI thd for CHASSIS_CONTROL_HARD_RESET
00 FA CHASSIS_CONTROL_POWER_DOWN req from the ACPI sensor (S5)
00 D9 CHASSIS_CONTROL_POWER_DOWN req from CPU0 temp sensor
01 0E CHASSIS_CONTROL_POWER_UP req from WakeOnLan sensor
Events Without Sensors
The BMC logs these events with a “sensor number” of 0; there is no matching SDR entry.
Triplet Event data2 data3 Notes
10:70:64 SEL almost full 1F %full The BMC logs this when the SEL is
75% full
12:70 : 0 4 B MC e n ter i n g firmwa re
update mode
12:70:05 SFW flash lnlock System firmware update in
progress
12:70:06 Front panel lock Disables all power and reset
requests from ipmi or sensors
12:F0:06 Front panel unlock
12:70:07 Firmware update app:
starting component update
12:F0:07 Firmware update app:
ending component update
12:70:80 BMC entering special
mode
Mode Mode is a bit-map:
Bit 0: Shmoo
Bit 1: MfgTest
Bit 2: Shutdown override
Bit 3: Fixed fan speed
Bit 4: Mfg
Bits 7-5: unused, set to 0
12:70 : A 1 BMC fi r mwa re i n i t i a l iz i n g M a jor F W
rev
Minor
FW rev
1D:70:00 BMC cold reset
1D:70:01 BMC warm reset
1D:70:02 BMC cold reset after SDRR
update