Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

18 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Overview
All information in this section is based on primary power consumptions with one power supply
installed.
Environmental Specifications
Operating temperature and humidity ranges may vary depending on the installed mass storage
devices. High humidity levels can cause improper disk operation. Low humidity levels can
aggravate static electricity problems and cause excessive wear of the disk surface.
Additional Component Power Consumption
Processor
SCSI hard disk drive (with I/O access)
SCSI hard disk (idle)
•PCI card
•AGP card
13 0 W
23W
16 W
10W to 25W
70W
443.6 Btu/h
78.4 Btu/h
54.5 Btu/h
34.12 Btu/h to 85.30 Btu/h
238.4 Btu/h
Environmental specifications (CPU with hard disk)
Operating temperature +5° C to +35° C (+41° F to +9 F)
Storage temperature -40° C to +70° C (-40° F to +158° F)
Over-temperature shutdown +40° C (+104° F)
Operating humidity 15% to 80% relative (noncondensing)
Storage humidity 8% to 85% relative (noncondensing)
Acoustic noise emission (ISO 7779)
Pedestal Server:
Typical configuration
1
(disk idle)
Maximum configuration
2
(disk idle)
Maximum configuration
2
(disk active)
Rack Server:
Typical configuration
1
(disk idle)
Maximum configuration
2
(disk idle)
Maximum configuration
2
(disk active)
1. Single processor, one to two SCSI hard disk drives and less than 8 GB of memory
2. Dual processor, one to two SCSI hard disk drives and less than 8 GB of memory
Sound power level
3
LwA
4
=5.1 BA
LwA =5.4
BA
LwA =6.2
BA
LwA =6.4 BA
LwA =6.4
BA
LwA =7.2
BA
3. Typical configuration at room temperature (25° C)
4. LwA = A-weighted sound power level in dB(A)
Operating altitude 3048 m (10,000 ft.) max
Storage altitude 4600 m (15,000 ft.) max