Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 45
System Configuration
Subnet, Gateway
Web Console Port Number
LAN hardware configuration (optional)
The Link State controls the speed at which the iLO MP card communicates with the
network.
Select auto-negotiate to enable the server to make the fastest possible connection.
The iLO MP card also negotiates to half or full duplex. This is the default,
recommended in most cases.
Select 10BaseT to force the iLO MP card to operate at the slower 10BaseT speed if
necessary for your network configuration. For example, if your network contains
both 10BaseT and 100BaseT connections, and you want the server to communicate
with the other 10BaseT connections, you must force it to operate at the slower speed.
NOTE: If you force the iLO MP card to operate at 10BaseT speed, it also operates at half duplex.
Make sure that your switch or hub is also in half duplex mode.
You can do the following in all options:
To change the setting, enter the appropriate information and press Enter.
To confirm your selections, enter Y and press Enter at the confirmation prompt.
3. To reset the iLO MP card, run the
xd command. The following displays, depending on the
server iLO MP firmware revision.
iLO MP firmware E.02.10:
xd
Non destructive tests:
1. Parameters checksum
2. I2C access (get Power Monitor status)
3. LAN access (PING)
4. Modem selftests
5. Secondary I2C access (get System status)
Type R to reset the MP or [Q] to quit the diagnostic menu.
-> Choice:
iLO MP firmware E.02.20 or higher:
XD
Diagnostics Menu:
Non destructive tests:
P - Parameter checksum
I - I2C access (get Power Monitor Status)
L - LAN access (PING)
M - Modem selftests
Destructive tests:
R - Restart the MP
Enter menu item or [Q] to Quit:
4. Select option 3 or L to ping the LAN and verify the LAN settings are correctly configured.
5. To reset the iLO MP card, enter
R and press Enter. (If prompted, enter Y and press Enter to
confirm the reset.)
Wait for the status message to clear:
The MP is now being reset...