Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 53
System Configuration
Connections Commands
Connections commands provide a means for examining and making connections or changing
modes.
Baseboard Management Controller
This section explains the Base Management Controller (BMC) command-line interface.
Accessing the BMC
To log in to the BMC command line interface, use a serial connection and terminal emulation
software, and follow these steps:
NOTE: The default terminal emulation type is VT100+. Terminal emulation for the BMC cannot
be changed. The default baud rate is 9600. This setting can be changed from the EFI Boot
Options Maintenance Menu.
1. With the server powered off, connect a null-modem cable to the serial console port 1 on the
rear panel of the server, and to your remote device.
2. Configure the terminal emulation software with the following settings:
Baud rate: 9600
Bits: 8
Parity: None
Stop Bits: 1 (one)
Flow Control: XON/XOFF
3. Using the terminal emulation, connect to the server with a direct connection.
4. Power on the server. The EFI menu displays in the terminal window.
5. To access the BMC command line interface, press:
Esc (
For example, on a U.S. QWERTY keyboard, press Esc, then press Shift and 9 at the same
time.
NOTE: If ac power is connected to the server, this command activates the BMC command line
interface even if the server power is off.
6. If prompted, enter the user or admin password at the login prompt:
login>
(You are not prompted for a password if none has been defined.)
Command Description
DI Disconnect remote or LAN connection
TE Send message to other user
WHO Display a list of connected users43