Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation
Bits Byte
7-2 1-0
HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 57
System Configuration
Long Format IPMI Response Data Structure Example
The BMC supports the version 1.0 IPMI categories and commands listed in the following tables.
For detailed information on the IPMI specification and commands, see the Intel web site at:
http://www.intel.com/design/servers/ipmi
Command Categories
Chassis Commands
Cmd = 0x04 0x04
Checksum = 0x08 0x08
rqSWID = 0xF0 0xF0
NetFn = 0x07 rsLUN = 0x00 0x1C
Checksum = 0xF4 0xF4
rsSA = 0x20 0x20
rqSeq = 0x01 rsLUN = 0x00 0x04
Cmd = 0x04 0x04
Data byte 1 = 0x00 (completion code) 0x00
Data byte 2 = 0x55 (result = no error) 0x55
Data byte 3 = 0x00 (details) 0x00
Checksum = 0x83 0x83
NetFn NetFn << 2 Description
00, 01 00, 04 Chassis
04, 05 10, 14 Sensor/Event (S/E)
06, 07 18, 1C Application
0A, 0B 28, 2C Storage
32, 33 C8, CC HP Custom (proprietary)
Command Description
01h Get chassis status
02h Chassis control
Bits Byte
7-2 1-0