Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation

HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide 71
Removing and Replacing Components
3.
Align the Front Bezel
Removing and Replacing Hot-Swappable and
Hot-Pluggable Devices
The rx2600 and zx6000 have hard disk drives that are hot-pluggable and power supplies and fans
that are hot-swappable. This section explains how to swap the following devices while the server
is running:
System fans
Power supplies
Hard drives
System Fans
There are four system fans that keep the server cool when it is running. The system fans are
hot-swappable. This enables you to replace a fan while the server is running.
CAUTION: When the server is running, you must replace the top cover within four minutes to prevent
components from overheating.
Removing a System Fan
To remove a system fan, follow these steps
1. Remove the server covers.
2. Remove the fan.
a. Grasp the appropriate fan and lift it out of the fan socket to remove it:
fan 1A, 1B, 2, or 3 from a rack-mounted server, or
fan 3 from a pedestal-mount server
1
2