80 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Removing and Replacing Components
Replacing the Processor Airflow Guide
To replace the processor airflow guide, follow these steps
1. Replace the front portion of the airflow guide:
a. Align the release latch of the front half of the airflow guide over the release latch post
and snap it in place.
b. Connect power connector on the front portion of the guide to the connector on the
system board.
c. Replace system fans 1A and 1B.
2. Replace the main portion of the airflow guide:
a. Hold the opening on top of the processor airflow guide.
b. At the same time, grasp the back end of the airflow guide and insert the airflow guide
into the server.
c. Connect the power cable and place the power and IDE cables in the cable clips.
d. Insert the two airflow guide retaining tabs into the two slots on the front half of the
airflow guide.
Replacing the Processor Airflow Guide
3. Replace the server covers.
4. Reconnect cables.
Removing and Replacing Memory
The server has 12 memory slots for installing DDR SDRAM memory modules. Modules can be
256 MB, 512 MB, 1 GB or 2 GB. The server supports combinations from 512 MB (zx6000) or 1
GB (rx2600) up to 24 GB. For HP approved memory modules.
NOTE: zx6000 workstations running Windows XP® 64-Bit Edition Version 2003 only support
up to 16 GB of RAM.