Operations and Maintenance Guide, Second Edition - HP Integrity rx2600 Server and HP zx6000 Workstation
98 HP Integrity rx2600 server and HP workstation zx6000 Operation and Maintenance Guide
Removing and Replacing Components
Locking the Processor in Place
7. Slide the sequencing retainer plate toward the front of the server.
Sliding Sequencer Retainer
8. Screw in the four heatsink captive screws.
Screw in the Heatsink and Processor Screws
9. Connect the power cable for the processor turbo fan to its connector on the system board.
10. Slide the processor power pod on the system board metal mounting bracket so that the
processor power pod connects to the processor. Align the two mounting screw holes on the
processor power pod with the holes on the system board metal mounting bracket. Screw in
the processor power pod mounting screws.
11. Replace the processor airflow guide, connect the power cable and power on the server.
12. Verify that the processor works:
❏ Run the info cpu command at the EFI shell prompt or,
❏ On servers with firmware version 2.0 or higher, check the configuration using the EFI
System Configuration menu.