HP Smart Array 5300 Controller User Guide

B
Electrostatic Discharge
To prevent damage to the system, be aware of the precautions you need to follow
when setting up the system or handling parts. A discharge of static electricity from a
finger or other conductor may damage system boards or other static-sensitive
devices. This type of damage may reduce the life expectancy of the device.
To prevent electrostatic damage, observe the following precautions:
Avoid hand contact by transporting and storing products in static-safe containers.
Keep electrostatic-sensitive parts in their containers until they arrive at static-free
workstations.
Place parts on a grounded surface before removing them from their containers.
Avoid touching pins, leads, or circuitry.
Always be properly grounded when touching a static-sensitive component or
assembly.
There are several methods for grounding. Use one or more of the following methods
when handling or installing electrostatic-sensitive parts:
Use a wrist strap connected by a ground cord to a grounded workstation or
computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm
resistance in the ground cords. To provide proper ground, wear the strap snug
against the skin.
Use heel straps, toe straps, or boot straps at standing workstations. Wear the
straps on both feet when standing on conductive floors or dissipating floor mats.
Use conductive field service tools.
HP Smart Array 5300 Controller User Guide B-1
HP CONFIDENTIAL
Writer: Kimberly Koch File Name: k-appb Electrostatic Discharge.doc
Codename: SilverHammer Part Number: 135606-006 Last Saved On: 3/13/03 2:01 PM