Windows Integrity Management Agents Reference

Capture chassis codes and contact HP Support.FirmwareError.9022
Contact HP Support to troubleshoot the cell and
either fix it or replace it.
Cell hardware problem like PDH memory itself,
the coherency controller, the executing CPU or
interaction between any of these cell components.9038
Troubleshoot the cell and either fix it or replace
it.
Cell hardware problem like PDH memory itself,
the CC chip, the executing CPU or interaction
between any of these cell components.9039
Troubleshoot the cell and either fix it or replace
it.
Cell hardware problem like PDH memory itself,
the CC chip, the executing CPU or interaction
between any of these cell components.9040
Upgrade PDC if this is found to be the problem
and a new PDC image is available.
PDC bug in which PDC thinks it was unable to
safely access PDH memory when maybe it really
could have.9041
Troubleshoot the cell and either fix it or replace
it.
Cell hardware problem like PDH memory itself,
the CC chip, the executing CPU or interaction
between any of these cell components.9042
An error during cell initialization occurred and
the cell will not be able to join the partition. Look
for other errors in the event log that articulate the
exact problem.9043
This is caused by the wrong type of complex
profile being loaded. System firmware will
default a new partition profile and continue on.9045
Troubleshoot the cell and either fix cell or replace
the cell board.
Cell hardware problem, like a problem with PDH
registers or PDH memory, or a problem with the
concorde or CPU chips.9046
Troubleshoot the cell and either fix cell or replace
the cell board.
Cell hardware problem, like a problem with PDH
registers or PDH memory, or a problem with the
concorde or CPU chips.9047
Troubleshoot the cell and either fix cell or replace
the cell board.
Cell hardware problem, like a problem with PDH
registers or PDH memory, or a problem with the
concorde or CPU chips.9049
Troubleshoot the cell and either fix cell or replace
the cell board.
Cell hardware problem, like a problem with PDH
registers or PDH memory, or a problem with the
concorde or CPU chips.9051
Troubleshoot the cell to find out if page zero
contents are screwed up or if hardware is just
failed to do the OS write or failed to do the PDC
read. Verify that memory is properly written and
holds contents at the page zero locations. Perhaps
replace the cell board or replace the memory.
Cell Hardware or memory problem that PDC
didn't catch.9052
Check CPU load ordering9084
Upgrade PDC if there is a version of PDC that
fixes such a problem.
PDC bug in which PDC is trying to access PDH
memory of a cell not in its partition.9364
Contact HP Support to confirm the PDH riser
card is functioning properly.Hardware problem with the PDH riser card.9365
Troubleshoot the fabric and reseat/replace the
cells or cables or backplane if necessary.
Hardware connecting cells in the partition
experienced a problem such that cells in the
partition together can no longer communicate.9367
Troubleshoot the cell and/or replace it.
Hardware problem with the CPU, CC, or PDH
flash.9368
Check for PDC upgrade
PDC bug such that PDC didn't log the relocation
address.9370
98 Management Agents Event Tables