Windows Integrity Management Agents Reference
Contact HP Support to check for PDC upgrade.PDC bug.9371
Troubleshoot the fabric and replace backplane or
cells. Gather event logs and contact HP Customer
Support for assistance.
Hardware connecting cells in the partition
experienced a problem such that cells in the
partition together can no longer communicate.9372
Troubleshoot the cell and/or replace it. Contact
HP Customer Support for assistance.
Hardware problem with the CPU chip, CC chip,
or PDH flash.9373
Troubleshoot the fabric and replace backplane or
cells. Contact HP Customer Support for
assistance.
Hardware connecting cells in the partition
experienced a problem such that cells in the
partition together can no longer communicate.9375
Upgrade PDC if there is a fix.PDC bug in which passed invalid arguments.9376
Reboot. If problem persists contact your HP
representative for support.MX2 initialization failed9379
Investigate the cause of the first core being
deconfigured
The second CPU in the Dual Core has been
deconfigured as a result of the first core being
deconfigured.9380
Reboot. If problem persists contact your HP
representative for support.FW failed to virtualize the mx2 interposer.9382
Reboot. If problem persists contact your HP
representative for support.Virtualizing the Dual Core Interposer has failed.9383
Reboot. If problem persists contact your HP
representative for support.Installation of the FW PMI handler has failed.9385
If this is in manufacturing, re-program the FRU
specific field of the FRU data for the cell or CPU
module. Otherwise, contact HP Support
personnel to troubleshoot the problem.
A Cell or CPU module's FRU data is programmed
incorrectly.9388
Contact HP Support personnel to troubleshoot
the Cell Board, Cell Power Board and PDH
Daughtercard.A hardware fault has occurred.9389
Contact HP Support personnel to troubleshoot
the Cell Board, Cell Power Board and PDH
Daughtercard.A hardware fault has occurred.9390
Fix the hardware, pdh riser or cell.Hardware failure.9391
Contact HP Support personnel to troubleshoot
the Cell Board, Cell Power Board and PDH
Daughtercard.A hardware fault has occurred.9392
All cpus on the cell have been scheduled for
deconfiguration. On the next reset, the cell will
no longer be operational; system firmware will
deconfigure all the cpus and this cell will not be
part of a partition. This action is not
recommended. To recover, the NVRAM on the
PDH card must be cleared, the cell power cycled,
and defaults restored from disk.9394
Check XBC, CC, links, etc.Fabric ReadError.9403
Contact HP Support personnel to check the Check
CC.Failure to read or write CC CSRs.9412
A power source has been removed from the
chassis.9417
A power source has been removed from the
chassis.9418
Platform Events – Table 2 (Windows System Log Event ID, Cause, Recommended Action) 99