HP Integrity rx2660 Server User Service Guide

2. If rack mounted, slide the server completely out from the rack. See “Extending the Server from
the Rack” (page 141).
3. Remove the top cover. See “Removing the Top Cover” (page 142).
4. Disconnect the internal SAS cables attached to the board. See Figure 79.
CAUTION: When disconnecting the SAS cables, note the labeling on the cables. When
reconnecting these cables, match each cable with the appropriate socket on the Smart Array
P400 controller. If the cables are mismatched, the server might not reboot. Both cables and
sockets are clearly marked with the correct channels.
Figure 79 Smart Array P400 Controller Location on System Board
431
RAID battery port on
the SAS Smart Array
P400 controller
SAS Smart Array P400
controller board lock
SAS Smart Array
P400 controller
2
SAS cable ports on
the SAS Smart Array
P400 controller
5. Disconnect the battery cable from the Smart Array P400 controller card.
6. Grasp the card by the edges and lift it out of the server.
Removing and Replacing the Smart Array P400 Controller and PCIe Expansion Board 189