HP Integrity rx2660 Server User Service Guide
CAUTION: If the server is expected to remain in standby mode for more than 30 minutes, AC
power should be completely removed from the server. You can do this by switching off the circuit
breakers which are part of the building installation, disconnecting or switching off a power
distribution unit, or by physically removing all power cords from the server.
NOTE: If the power restore feature is set to Always On through the iLO 2 MP PR command, the
server automatically powers on to the full power state when the power cord is plugged in to the
server.
Figure 32 Rear Panel Control, Port, and LED Locations
10
iLO 2 MP LAN port
6
Auxiliary serial port
1
Power supply 1 and LED
2
Power supply 2 and LED
11
iLO 2 MP status LEDs
7
VGA port
8
USB ports
3
PCI-X/PCIe slots
12
iLO 2 MP reset
1394
Core LAN ports UID button/LEDConsole serial port
5
Smart Array P400
controller slot
NOTE: The Office Friendly server is shown in Figure 32 (page 64). The Data Center server might
only have one power supply installed.
Applying Standby Power to the Server
To apply standby power to the server:
64 Installing the Server