HP Integrity Servers with Microsoft Windows Server 2008 SP2 Release Notes v7.1

4. Boot to the EFI Shell.
5. Run the ASPM/MSI-X Vector Update utility (set_msi_vect.nsh). When
prompted, select Option #1 (“Load preload table with 32 MSI-x vectors +
ASPM fix”).
6. Boot the system.
7. Install Microsoft Quick Fix Engineering update QFE 957018. For more
information, see the Microsoft Knowledge Base article 957018, available
at: http://support.microsoft.com/kb/957018/en-us. You can also find this
update on your HP Smart Update media. Look in the OS Updates section
on the QFEs for WS2008 tab.
Boot Controller
If you are installing to or booting from the AH400A or AH401A, follow these
steps:
1. Download the ASPM/MSI-X Vector Update utility to a USB flash drive from
ftp://ftp.hp.com/pub/servers/software/WindowsIntegrity/ before booting
the OS. See the latest version of the Release Notes at http://docs.hp.com
for the latest information about this utility and file name.
2. Install the controller.
3. Boot to the EFI Shell.
4. Run the ASPM/MSI-X Vector Update utility (set_msi_vect.nsh). When
prompted, select Option #2 (“Load preload table with 2 MSI-x vectors +
ASPM fix”).
5. Install the operating system to the controller.
6. Install Microsoft Quick Fix Engineering update QFE 957018. For more
information, see the Microsoft Knowledge Base article 957018, available
at: http://support.microsoft.com/kb/957018/en-us. You can also find this
update on your HP Smart Update media. Look in the OS Updates section
on the QFEs for WS2008 tab.
After the QFE is installed, you can set the number of supported MSI-X vectors
supported back to 32 by running the update utility from the EFI shell and selecting
option 1 to "Load preload table with 32 MSI-x vectors + ASPM fix."
Boot from Emulex HBA fails
Issue Microsoft Windows Server 2008 installations booting from Emulex Host Bus
Adapters result in a Stopcode 0xD1 or Stopcode 0x50 when updating the driver
using the Support Pack or Smart component.
Servers All Integrity
Workaround Manually load the driver using the Integrity Boot From SAN driver available at
http://www.hp.com during the initial phase of the installation process. For
information, see the HP StorageWorks Booting Windows for Itanium-based systems
from a storage area network document at http://www.hp.com.
Device manager error after kit update
Issue After updating the HP Storageworks Fibre Channel Adapter Kit for the Emulex
Storport driver and HBAnyware utility from the in-box version to the version on
the Smart Setup CD, when viewing the controller in the device manager, yellow
exclamations marks (!) appear next to the Emulex controller with the following
error message:
This device cannot start (Code 10)
Troubleshooting Common Issues 19