HP Integrity Servers with Microsoft Windows Server 2008 SP2 Release Notes v7.1

Servers All Integrity
Workaround The controllers start up normally and function properly after rebooting the system.
Target LUN and boot controller WWN not visible in a VC environment
Issue When installing to storage attached to an Emulex LPe1105 mezzanine controller
(403621-B21) in a Virtual Connect (VC) environment through a Brocade switch,
the target LUN is not visible and the WWN for the boot controller is not visible
in the zone in the switch administrative tool.
Servers HP Integrity BL860c Server Blade and BL870c Server Blade
Workaround Write down and save the controller World-Wide Number (WWN) when installing
it into the system, or obtain it from the VC manager or EFI utility. Then, manually
enter the WWN into the desired zone on the switch when configuring the zone.
Scan for targets and continue with the usual installation steps to boot from the
controller. For more information, see the HP StorageWorks Booting Windows for
Itanium-based systems from a storage area network document at http://
www.hp.com.
HP Smart Update Manager
QLogic driver does not install successfully
Issue If you have multiple QLogic cards in your system, HP SUM might not update the
driver for some of the cards.
Servers All Integrity
Workaround Run HP SUM or the particular QLogic smart component again with force install
to update the driver.
Installation
Integrity PCI-express power management fix for AH400A/AH401A is always ready to install
Issue The Integrity PCI-express power management fix for the AH400A and AH401A
HBAs (cp009436.exe) is always ready to install” even after it is installed. This
can occur when running HP SUM interactively from the Smart Setup CD or after
you download the Support Pack from the web and run it interactively.
Servers All Integrity
Workaround There is no workaround. You can ignore this message after you install the
package.
HP SUM does not detect installed version of Neterion 10Gb NIC driver
Issue If the Neterion 10 Gb NIC (AD385A) driver is already installed with the
Reinstallation DVD, and HP SUM is run for the first time, the driver is displayed
in the install required group, instead of already installed one. When the smart
component is executed, it identifies the installed driver is same as the available
version and does not execute the installation.
Servers Superdome SX2000, rx8640, rx7640, rx6600, rx3600, rx2660
Workaround Run HP SUM with the force option. See the Windows Server 2008 SP2 on Integrity
Servers Installation Guide.
A non-existant Slot 14 is reported as the location of a device
Issue The Windows Device Manager reports the location of a device as Slot 14, which
is non-existent.
20 Release 7.1 Overview