Installation Guide - HP AD397A rx2660 SAS Smart Array P400 Controller
Installing the SAS Smart Array P400 Controller
Checking and Updating Smart Array P400 Controller Firmware
Chapter 1
18
Verifying the Firmware Update
After updating the firmware, cycle the power on the system and on any external JBODS connected to the
system.
After performing the firmware update, use LIST to confirm that the correct firmware version is installed; see
“Checking the Controller Firmware” on page 15. For example:
fs0:\EFI\TOOLS> saupdate list
********************************************************************************
Smart Array Offline Firmware Update Utility
Version 2.06.10.03
(C) Copyright 2006 Hewlett-Packard Development Company, L.P.
********************************************************************************
Seg Bus Dev Func Description Version
0 52 0 0 HP Smart Array P400 2.08
HELP or ?
Use HELP or ? to display usage text, program version number, and build date:
Enter: saupdate HELP
or
saupdate ?
Error Messages
The following error messages may appear when using the saupdate utility:
• When keyword LIST or UPDATE is misspelled or extra parameters are specified:
Error: Syntax Error
Usage: saupdate LIST or saupdate UPDATE [ | all ]
• When the controller ID in the saupdate UPDATE command is not correct:
No matching controller found
• When a firmware file does not exist in the saupdate UPDATE command, the example shows:
SPAWN208242.BIN does not exist.
File SPAWN208242.BIN: Not Found
• When an invalid firmware or corrupted file is specified in the saupdate UPDATE command, the example
shows: SPAWN208242.BIN does not exist.
File SPAWN208242.BIN: invalid or corrupted