HP Integrity rx2660 Server Pedestal Installation Guide HP Part Number: AB419-9011A Published: April 2007 Edition: 1
© Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
Table of Contents About This Document.........................................................................................................5 Intended Audience.................................................................................................................................5 Document Organization.........................................................................................................................5 Typographic Conventions.....................................................
List of Figures 2-1 2-2 2-3 2-4 2-5 2-6 2-7 3-1 4-1 4-2 4-3 4-4 4-5 Removing the Rails from the Server...............................................................................................8 Front of Server.................................................................................................................................9 Installing the Pedestal Bottom Piece.............................................................................................10 Attaching the Bezel Cover.........
About This Document This document describes how to convert the HP Integrity rx2660 server from a rack system to a pedestal system. The document printing date and part number indicate the document’s current edition. The printing date changes when a new edition is printed. Minor changes may be made at reprint without changing the printing date. The document part number also changes when extensive changes are made. Document updates may be issued between editions to correct errors or document product changes.
The Rack System /E User's Manual can be found at: http://www.hp.com under Enterprise Rack & Power Products. Publishing History This table lists the publishing history of this document. Document Manufacturing Part Number Publication Date 5991-5956 November 2006 AB419-9011A April 2007 HP Encourages Your Comments HP encourages your comments concerning this document. We are committed to providing documentation that meets your needs.
1 Important Warnings Electricity Electrical Grounding WARNING! For your safety always connect the equipment to a grounded wall outlet. Always use a power cord with a properly grounded plug, such as the one provided with the equipment, or one in compliance with your national safety standards. This equipment can be disconnected from the power by removing the power cord from the power outlet. This means the equipment must be located close to an easily accessible power outlet.
2 Installing the Server into the Pedestal Kit Use this chapter to install your rx2660 to a pedestal kit. The following are the high-level procedures needed to install the rx2660 server into a pedestal kit. 1. Remove the rack-mount rails from the server (if necessary). 2. Install the pedestal kit top and bottom pieces. 3. Install the bezel cover. 4. Install the pedestal kit left side piece. 5. Install the pedestal kit right side piece. 6. Install the pedestal kit feet.
Installing the Pedestal Kit Top and Bottom IMPORTANT: In this document the server top, bottom, right and left always refer to the server as faced from the front with the server in a horizontal orientation. The pedestal kit components are referred to by their final position with the server in a vertical orientation. For example, the pedestal kit bottom attaches to the server left side. See Figure 2-2 (page 9) for the server and pedestal orientations.
The pedestal kit bottom attaches to the left side of the server when the server is in the horizontal position. The pedestal kit top attaches to the right side of the server when the server is in the horizontal position. The pedestal bottom may be distinguished from the pedestal top by the pedestal feet slots. The pedestal top for the HP Integrity rx2660 server contains windows through which server information, such as the MAC address, can be read.
4. Stand the server up on the bottom piece of the pedestal kit that was just installed so the server is in the vertical position. CAUTION: The server is heavy. Be careful when lifting it to the vertical position. Without the feet installed, the server may tip over easily. Be careful when working near the server to avoid tipping it over. NOTE: The allen wrench may interfere with installing the pedestal kit top piece.
Installing the Pedestal Kit Left Side Piece The pedestal kit left side piece attaches to the top of the server. The top cover of the Office Friendly server has ventilation holes in it to allow for proper air flow and cooling. The left side piece of the pedestal kit also has ventilation holes in it to allow for the proper cooling and air flow. Follow these steps to attach the pedestal kit left side piece.
Installing the Pedestal Kit Right Side Piece The pedestal kit right side piece attaches to the bottom of the server. The bottom of the Office Friendly server does not have ventilation holes in it, and the right side piece of the pedestal kit does not have ventilation holes in it. Follow these steps to attach the pedestal kit right side piece. IMPORTANT: Ensure the pedestal kit piece that you are installing onto the right side of the pedestal (the bottom of the server) does not have ventilation holes in it.
Installing the Pedestal Feet The pedestal feet slide into the slots on the pedestal bottom, two on each side. The feet are all the same and can be mounted in any slot on the bottom piece of the pedestal kit. See Figure 2-7 (page 14).
3 Accessing Internal Components for a Pedestal–Mounted Server Follow this procedure to access internal components for a pedestal-mounted server. 1. Power down the server and remove all cables. 2. Remove the pedestal kit feet. 3. Lay the server on the right side (facing the front of the server). The left side of the pedestal kit (with the ventilation holes) should be facing up. 4. Unscrew the captive thumbscrews on the rear of the pedestal kit for the left side pedestal kit piece. 5.
4 Removing the Server from the Pedestal Kit Use this chapter to remove the server from the pedestal kit. The following are the high-level procedures needed to remove the rx2660 server from the pedestal kit. 1. Remove pedestal feet. 2. Remove the pedestal side pieces. 3. Remove the bezel cover. 4. Remove the pedestal top piece. 5. Remove the pedestal bottom piece.
Removing the Pedestal Kit Feet CAUTION: The server is able to stand in the vertical position without the feet installed, but may tip easily. Remove the pedestal kit feet by pulling the feet outward.
Removing the Pedestal Sides Follow these steps to remove the pedestal sides. 1. Unscrew the thumb screws in the rear of the server. See Figure 4-2 (page 18). Figure 4-2 Unscrewing the Thumbscrews 2. 3. 4. 18 Pull back on the side component using the finger grips. Once the pedestal side has moved about 1/4 inch the side can be removed. Repeat these steps for the other panel.
Removing the Bezel Cover To remove the bezel cover: 1. Release the locking tabs behind the top corners of the bezel cover. See Figure 4-3. The view in the picture is from the rear of the server looking toward the front of the server. 2. Pull the bezel cover away from the server. Figure 4-3 Locking Tabs 1 2 Right locking tab Left locking tab Removing the Pedestal Top and Bottom Follow these steps to remove the pedestal top and bottom components. 1.
Figure 4-4 Unlocking the Pedestal Top Piece from the Server 3. 4. 5. 6. 20 Slide the pedestal top piece toward the back of the server to release it from the server. Once the pedestal component has moved about 1/4 inch, the lock releases, and you can remove the screwdriver. Pull the pedestal kit top piece away from the server. Lay the server flat on the server top (upside down) with the pedestal kit bottom piece hanging off the work surface.
NOTE: Since the pedestal kit bottom piece is taller than the server when installed, the pedestal kit bottom piece must hang off the work surface to allow its removal. If you cannot do this, then place something non-static under the server to raise it about 8 cm (3 in.) off of the work surface to allow the pedestal kit bottom piece removal. Figure 4-5 Removing the Pedestal Kit Bottom Piece 3 Pedestal kit bottom piece Work surface 2 Server bottom 4 Pedestal kit bottom piece lock 7.
*AB419-9011A* Printed in the US