Windows Integrity Management Agents Reference

Event DescriptionEvent SeverityEvent ID
Storage System Temperature Failure.%nThe %6 %7 storage system connected to SCSI
bus %5 of the controller in slot %4 has a failed temperature status. Shutdown the
storage system as soon as possible.%n [SNMP TRAP: 8009 in CPQSTSYS.MIB]Error1076
Storage System Temperature Degraded.%nThe %6 %7 storage system connected to
SCSI bus %5 of the controller in slot %4 system has a temperature outside the normal
operating range.%n [SNMP TRAP: 8010 in CPQSTSYS.MIB]Warning1077
Storage System Temperature OK.%nThe temperature in the %6 %7 storage system
connected to SCSI bus %5 of the controller in slot %4 has returned to the normal
operating range.%n [SNMP TRAP: 8011 in CPQSTSYS.MIB]Informational1078
Drive Array Physical Drive Monitoring is not enabled. The physical drive in slot %4,
port %5, bay %6 with serial number "%7", does not have drive threshold monitoring
enabled.Informational1098
Storage System Side Panel Removed.%nThe side panel has been removed on the %6
%7 storage system connected to SCSI bus %5 of the controller in slot %4.%n [SNMP
TRAP: 8013 in CPQSTSYS.MIB]Warning1101
Storage System Side Panel In Place.%nThe side panel has been replaced on the %6
%7 storage system connected to SCSI bus %5 of the controller in slot %4.%n [SNMP
TRAP: 8012 in CPQSTSYS.MIB]Informational1102
Storage System Fault Tolerant Power Supply Degraded.%nThe fault tolerant power
supply in the %6 %7 storage system connected to SCSI bus %5 of the controller in
slot %4 has a degraded status. Restore power or replace any failed power supply.%n
[SNMP TRAP: 8015 in CPQSTSYS.MIB]Warning1104
SCSI Tape Drive Status Change.%nThe tape drive with SCSI target %6 connected to
SCSI bus %5 of the controller in slot %4 has a new status of %2.%n(Tape drive status
values: 1=other, 2=ok, 3=failed, 5=offline, 6=missingWasOk, 7=missingWasFailed,
8=missingWasOffline)%n [SNMP TRAP: 5016 in CPQSCSI.MIB]Error1107
SCSI Tape Drive Head Needs Cleaning.%nThe tape drive with SCSI target %6
connected to SCSI bus %5 of the controller in slot %4 needs to have a cleaning tape
inserted and run.%n [SNMP TRAP: 5008 in CPQSCSI.MIB]Warning1119
SCSI Tape Drive Cleaning Tape Needs Replacing.%nThe tape drive with SCSI target
%6 connected to SCSI bus %5 of the controller in slot %4 needs the cleaning tape
replaced.%n [SNMP TRAP: 5009 in CPQSCSI.MIB]Warning1120
IDE Drive Status Degraded.%nThe IDE drive %4 has a degraded status and should
be scheduled for replacement.%n [SNMP TRAP: 14001 in CPQIDE.MIB]Warning1121
IDE Drive Status OK.%nThe IDE drive %4 has returned to a normal operating
condition.%n [SNMP TRAP: 14002 in CPQIDE.MIB]Informational1122
External Array Logical Drive Status Change. Logical drive number %5 on array "%4"
has a new status of %6.%n(Logical Drive status values: 1=other, 2=ok, 3=failed,
4=unconfigured, 5=recovering, 6=readyForRebuild, 7=rebuilding, 8=wrongDrive,
9=badConnect, 10=overheating, 11=shutdown, 12=expanding, 13=notAvailable,
14=queuedForExpansion)%n [SNMP TRAP: 16022 in CPQFCA.MIB]Error1145
External Array Physical Drive Status Change. The physical drive in port %5, bay %6
on array "%4" has a new status of %7.%n(Drive status values: 1=other, 2=unconfigured,
3=ok, 4=threshExceeded, 5=predictiveFailure, 6=failed)%n [SNMP TRAP: 16016 in
CPQFCA.MIB]Error1146
External Array Spare Drive Status Change. The spare drive in port %5, bay %6 on
array "%4" has a new status of %7.%n(Spare status values: 1=other, 2=inactive, 3=failed,
4=building, 5=active)%n [SNMP TRAP: 16002 in CPQFCA.MIB]Error1147
External Array Accelerator Status Change. The array accelerator board attached to
the external controller in I/O slot %5 of array "%4" has a new status of
%6.%n(Accelerator status values: 1=other, 2=notConfigured, 3=enabled,
4=tmpDisabled, 5=permDisabled)%n [SNMP TRAP: 16017 in CPQFCA.MIB]Error1148
120 Management Agents Event Tables