HP Integrity rx2660 Server User Service Guide
Figure 62 Removing and Replacing the Fan / Display Board
3
Keyways on the fan/display board
1
Cables connected to the fan/display board
2 4
Captive thumbscrews Fan/display board
NOTE: Figure 62 (page 168) shows the Data Center fan/display board. The Office Friendly board
is nearly identical.
Replacing the Fan / Display Board
To replace the fan/display board:
1. Align the connectors with the openings on the front bezel and place the fan/display board
onto the guide pins. Shuttle the board toward the front of the server until it locks into place (3).
2. Turn the knurled thumb screws clockwise until the board is secured into place (2).
3. Reconnect the five cables into the connectors on the fan/display board (1).
4. Replace the fan carrier. See “Replacing the Fan Carrier Assembly” (page 160).
5. Replace the top cover. See “Replacing the Top Cover” (page 142).
6. If rack mounted, slide the server completely into the rack. See “Inserting the Server into the
Rack” (page 141).
168 Removing and Replacing Server Components