HP Insight Management WBEM Provider Events Reference Guide

Power was forced to ON without permission from the Onboard Administrator.
Probable Cause: A forced power on occurred. Usually this is performed when a
normal power on request is denied. The Onboard Administrator may now be running
in a non-redundant or over-budget power configuration. Recommended Action:
Make sure Onboard Administrator has the appropriate number and configuration
of power supplies. Reduce power required by the blade (for instance, remove some
memory or a CPU.) Or, if there are powered-on blades that are not in use, power
them off. WBEM EventID: 9901. WBEM ProviderName: FPL_IndicationProvider.Warning14590
Integrated Lights Out unable to communicate with OA after multiple retries. Probable
Cause: iLO has repeatedly requested communication with the Onboard Administrator
and has not received a response. This may be because the EM has a fault condition,
or is busy, being reset, or removed. Recommended Action: The communication loss
may have been temporary and nothing needs to be done if the communication is
now working. Check the Fault LED on the enclosure manager. Reset the enclosure
manager. Reset iLO. Replace the enclosure manager. WBEM EventID: 9902. WBEM
ProviderName: FPL_IndicationProvider.Warning14593
System Firmware internal error detected resulting in execution of ASSERT macro.
Probable Cause: The cause is unknown. Recommended Action: Examine previous
events and ASCII information following this event for more information. Ensure
firmware is at the current supported revision. If problem persists, contact support.
WBEM EventID: 9985. WBEM ProviderName: FPL_IndicationProvider.Error14605
System Firmware internal error detected resulting in execution of ASSERT macro.
Probable Cause: The cause is unknown. Recommended Action: Examine previous
events and ASCII information following this event for more information. If problem
persists, contact support. WBEM EventID: 9986. WBEM ProviderName:
FPL_IndicationProvider.Warning14606
System Firmware internal ASSERT source code line number. WBEM EventID: 10557.
WBEM ProviderName: FPL_IndicationProvider.Warning14609
System Firmware internal ASSERT module name. Probable Cause: Assert has been
encountered. Recommended Action: Assemble the module name and line information.
Contact support with this information. WBEM EventID: 10558. WBEM ProviderName:
FPL_IndicationProvider.Warning14610
Thread has failed Early Self-test and is now operating with degraded performance.
Probable Cause: Thread has failed early self-test. Recommended Action: Reboot the
system. If the problem persists, contact support for help to replace the CPU. WBEM
EventID: 9990. WBEM ProviderName: FPL_IndicationProvider.Warning14616
The PDH Controller has experienced an unexpected reboot. Probable Cause: The
PDHC kernel detected a HW or SW error that causes the PDHC kernel to crash.
Recommended Action: Decode the event payload for specific crash reason. WBEM
EventID: 9996. WBEM ProviderName: FPL_IndicationProvider.Warning14634
Failed to notify manageability of a change to the real-time-clock device. Probable
Cause: The EFI subsystem could not notify manageability of a change to the
real-time-clock device. Recommended Action: Verify Firmware is at the current
supported revision. Reset the system. WBEM EventID: 10065. WBEM ProviderName:
FPL_IndicationProvider.Warning14645
ACPI parser error due to a missing AML identifier. Probable Cause: The ACPI
subsystem could not find the doorbell AML identifier while parsing the DSDT table.
Recommended Action: Ensure FW is at the current supported revison. WBEM
EventID: 10067. WBEM ProviderName: FPL_IndicationProvider.Error14670
Memory Configuration rendevous failed. Probable Cause: Read from non-volatile
memory failed. Recommended Action: Verify the FW is at current supported revision.
Reset the system and attempt to reboot again. If problem persists, contact support.
WBEM EventID: 10072. WBEM ProviderName: FPL_IndicationProvider.Warning14685
Platform Events 101