HP Insight Management WBEM Provider Events Reference Guide

System event log almost full. Probable Cause: The System Event Log is almost full.
Recommended Action: Review the log for any important events, then clear it. WBEM
EventID: 163. WBEM ProviderName: SEL02_IndicationProvider.Warning15105
BMC entering special mode. Probable Cause: BMC entering special mode. The system
is not operating in a normal configuration. Some protection features may be disabled
in this mode. Recommended Action: The Special Mode must be exited to ensure
proper operation of the server. WBEM EventID: 166. WBEM ProviderName:
SEL02_IndicationProvider.Warning15106
TOC interrupt (crash dump). Probable Cause: The critical interrupt sensor has detected
that there was a Diagnostic Interrupt initiated by IPMI command. Either the Transfer
Of Control (TOC) button was pressed or the interrupt was initiated remotely. The
system will reboot after the interrupt processing is finished. Recommended Action:
If this is unexpected behavior, then check logs for events that would have caused an
INIT, TOC, or RESET. WBEM EventID: 169. WBEM ProviderName:
SEL02_IndicationProvider.Error15108
ACPI state S5 (soft-off, entered by override). Probable Cause: The system has been
powered OFF with a hard power-down. Recommended Action: HP recommends
that when you powered down the system you use the normal shutdown procedure
to properly shut down the operating system. Otherwise, data-loss and/or hardware
failure can occur. WBEM EventID: 176. WBEM ProviderName:
SEL02_IndicationProvider.Warning15115
Watchdog timer expired - hard reset. Probable Cause: Watchdog timer expired, and
a hard reset of the system occurred. Recommended Action: Some process took longer
than it should. Identify that process and contact the vendor of that application. WBEM
EventID: 178. WBEM ProviderName: SEL02_IndicationProvider.Error15117
Watchdog timer expired - power-off. Probable Cause: Watchdog timer expired, and
the system was powered-off. Recommended Action: Some process took longer than
it should. Identify that process and contact the vendor of that application. WBEM
EventID: 179. WBEM ProviderName: SEL02_IndicationProvider.Error15118
Watchdog timer expired - power-cycle. Probable Cause: Watchdog timer expired,
and the system was power-cycled. Recommended Action: Some process took longer
than it should. Identify that process and contact the vendor of that application. WBEM
EventID: 180. WBEM ProviderName: SEL02_IndicationProvider.Error15119
Missing FRU device. Probable Cause: A required device was not detected. See the
System Event Log (SEL). Recommended Action: Install missing, required device.
WBEM EventID: 182. WBEM ProviderName: SEL02_IndicationProvider.Error15121
Missing Entity. Probable Cause: A required device was not detected. Recommended
Action: Install missing, required device. WBEM EventID: 183. WBEM ProviderName:
SEL02_IndicationProvider.Error15122
PCI parity error detected. Probable Cause: An I/O device (or host bridge) detected a
bus parity error, OR An I/O device (or host bridge) mastered a bus transaction and
received a parity error response from the target. Recommended Action: For an I/O
bus parity error, consult the error logs for additional information. Determine and
replace the failed I/O device. For an I/O host bridge failure, contact your HP
representative to check the I/O host bridge. WBEM EventID: 171. WBEM
ProviderName: SEL02_IndicationProvider.Warning15124
PCI system error detected. Probable Cause: An I/O device (or host bridge) detected
an internal error. OR An I/O device (or host bridge) detected a bus error.
Recommended Action: For an I/O device failure, consult the error logs for additional
information. Determine and replace the failed I/O device. For an I/O host bridge
failure, contact your HP representative to check the I/O host bridge. WBEM EventID:
172. WBEM ProviderName: SEL02_IndicationProvider.Warning15125
Power failure in power supply. Probable Cause: Indicates a failure with the AC power
source that is connected to one of the redundant power supply units. Recommended
Action: Check the power cord or source voltage. WBEM EventID: 155. WBEM
ProviderName: SEL02_IndicationProvider.Error15724