HP Insight Management WBEM Provider Events Reference Guide

Voltage reached critical level. Probable Cause: The voltage in the server has gone
outside the factory set range. A bad component, blown fuse, poorly seated module,
loose cable, or debris could be responsible for this failure. Recommended Action:
Check all boards, power supplies, and modules that either supply or use this voltage
rail. WBEM EventID: 119. WBEM ProviderName: SEL02_IndicationProvider.Error15726
System shut-down or reset caused by sensor reading. Probable Cause: A sensor
reading in the system was determined to be non-recoverable and the system was
shut down or reset. Recommended Action: Read the system logs to find which sensor
was out of range. WBEM EventID: 167. WBEM ProviderName:
SEL02_IndicationProvider.Error15727
The BMC firmware did not detect the system firmware boot. Probable Cause: Possible
Causes: 1. Bad System Firmware image in ROM 2. Power not reaching processors 3.
Processor is in reset or is not properly seated in system 4. An unsupported processor
was inserted in system 5. Communication with BMC is impaired. Recommended
Action: To correct the problem, try the following: 1. Validate that processors are
supported in this system. 2. Verify that processors are seated properly in system. 3.
Check if system has booted (only a communication problem. - future events will also
be lost.) 4. Attempt a system reset, INIT, and/or A/C cycle to clear the problem. 5.
Update system firmware again if necessary. WBEM EventID: 132. WBEM
ProviderName: SEL02_IndicationProvider.Error15728
A/C Power failed, disconnected, or out of range. Probable Cause: The input power
to the supply has failed or gone out of range. Or the input cord has been disconnected.
Recommended Action: Check the power cord or source voltage. WBEM EventID:
154. WBEM ProviderName: SEL02_IndicationProvider.Error15729
The power supply sensors detect a possible problem. Probable Cause: The power
supply fan(s) is slowing. Recommended Action: Check power supply fan(s). WBEM
EventID: 138. WBEM ProviderName: SEL02_IndicationProvider.Warning15730
Uncorrectable multi-bit ECC error has occurred. Probable Cause: There has been an
ECC double-bit error in one of the server's ECC memory modules. When an ECC
double-bit memory error is detected, the system generates a Non-Maskable Interrupt
that halts the system to prevent errors from propagating to other subsystems. Data
being written or transmitted at the time may have been lost. Recommended Action:
Make a note of the failed memory bank/board number and slot number, contact HP
support to replace the failed module. WBEM EventID: 159. WBEM ProviderName:
SEL02_IndicationProvider.Error15731
Temperature sensor crossed upper non-critical threshold. Probable Cause: The
temperature inside the server has gone outside the factory specified range for normal
operation. You should quit applications and power down the server to protect its
hardware from damage. This event may indicate one of the following conditions: A
failed fan, blocked air vents or poor ventilation around the server, open server chassis
cover, or missing drive slot covers, high temperature in the room where the server
resides, an unusually hot hardware component located near one of the server's
temperature sensors. Recommended Action: You should quit applications and
shutdown the system. Find cause of temperature anomaly and fix it. WBEM EventID:
100. WBEM ProviderName: SEL02_IndicationProvider.Warning15732
A temperature inside the server went far outside the factory specified range. Probable
Cause: The temperature inside the server has gone far outside the factory specified
range for normal operation. To avoid permanent damage to your server hardware,
go and turn off the server immediately. This event may indicate one of the following
conditions: a failed fan blocked air vents or poor ventilation around the server open
server chassis cover, or missing drive slot covers high temperature in the room where
the server resides an unusually hot hardware component located near one of the
server's temperature sensors. Recommended Action: Shutdown the system
immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 101.
WBEM ProviderName: SEL02_IndicationProvider.Error15733
106 WBEM Provider Event Tables