HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
Pal proc error getting pal copy info. Probable Cause: PAL_COPY_PAL_INFO call
returned a failure. Recommended Action: Reboot, if problem persists contact your
HP representative for support. WBEM EventID: 243. WBEM ProviderName:
FPL_IndicationProvider.Error5077
Pal proc error copying pal to memory. Probable Cause: There has been an error
copying PAL to memory. Recommended Action: Reboot, if problem persists contact
your HP representative for support. WBEM EventID: 244. WBEM ProviderName:
FPL_IndicationProvider.Error5078
Boot pal proc failure. Probable Cause: Internal PAL Error. Recommended Action:
Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 245. WBEM ProviderName: FPL_IndicationProvider.Warning5079
Console device failure. Probable Cause: A console device has failed. Recommended
Action: Reset console device/system. WBEM EventID: 246. WBEM ProviderName:
FPL_IndicationProvider.Warning5080
Platform interface device failure. Probable Cause: A console device has failed.
Recommended Action: Reset console device/system. If problem persists contact your
HP representative for support. WBEM EventID: 247. WBEM ProviderName:
FPL_IndicationProvider.Warning5081
platform scratch RAM test failed. Probable Cause: Bad or corrupt Scratch RAM.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 248. WBEM ProviderName: FPL_IndicationProvider.Warning5082
CPU rendezvous failure. Probable Cause: Bad or slow CPU. Recommended Action:
Replace CPU. WBEM EventID: 249. WBEM ProviderName: FPL_IndicationProvider.Warning5083
Error extracting sal_b from rom. Probable Cause: ROM Corrupt or unreadable.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 250. WBEM ProviderName: FPL_IndicationProvider.Error5084
Scratch RAM bad. Probable Cause: Bad or corrupt Scratch RAM. Recommended
Action: Reboot, if problem persists contact your HP representative for support. WBEM
EventID: 251. WBEM ProviderName: FPL_IndicationProvider.Error5085
IPMI System Event Log (SEL) is full. Probable Cause: IPMI SEL full. Recommended
Action: Clear SEL through BMC or MP. WBEM EventID: 252. WBEM ProviderName:
FPL_IndicationProvider.Warning5087
Slave wakeup before vector registered. Probable Cause: No wakeup vector registered
for processor. Recommended Action: Reboot, if problem persists contact your HP
representative for support. WBEM EventID: 253. WBEM ProviderName:
FPL_IndicationProvider.Warning5091
CPU failed rendezvous handler. Probable Cause: SFW is unable to determine the
FSB speed. Recommended Action: Reboot, if problem persists contact your HP
representative for support. WBEM EventID: 254. WBEM ProviderName:
FPL_IndicationProvider.Warning5092
Error building SMBIOS Tables. Probable Cause: SFW failed to build the SMBIOS
tables. Recommended Action: If SMBIOS is preventing functionality, reboot. If
problem persists contact your HP representative for support. WBEM EventID: 255.
WBEM ProviderName: FPL_IndicationProvider.Error5098
Trap nest limit exceeded. Probable Cause: The trap nesting limit has been exceeded.
Recommended Action: Reboot if necessary, if problem persists contact your HP
representative for support. WBEM EventID: 256. WBEM ProviderName:
FPL_IndicationProvider.Error5100
Trap not serviced. Probable Cause: A invalid trap has been requested or a trap has
not been installed. Recommended Action: Reboot if necessary, if problem persists
contact your HP representative for support. WBEM EventID: 257. WBEM
ProviderName: FPL_IndicationProvider.Error5101
16 WBEM Provider Event Tables