HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
PCI slot's standby power failed. Probable Cause: I/O slot failure. Recommended
Action: Reseat IO card. Replace IO card. If problem persists, contact your HP
representative to check the I/O slot. WBEM EventID: 287. WBEM ProviderName:
FPL_IndicationProvider.Warning5147
Found invalid PCIXCAP value. Probable Cause: I/O host bridge failure. Hot-plug
controller failure. Recommended Action: Contact your HP representative to check
the I/O host bridge or the hot-plug controller. WBEM EventID: 288. WBEM
ProviderName: FPL_IndicationProvider.Warning5148
Unsupported rope frequency. Probable Cause: Internal firmware error. Recommended
Action: Contact your HP representative to check the firmware. WBEM EventID: 289.
WBEM ProviderName: FPL_IndicationProvider.Warning5149
Unsupported host bridge type. Probable Cause: Firmware needs to be updated. An
incorrect I/O backplane is installed. Recommended Action: Contact your HP
representative to check the firmware and the I/O backplane. WBEM EventID: 290.
WBEM ProviderName: FPL_IndicationProvider.Warning5150
Machine Check initiated. Probable Cause: A Machine Check has occurred.
Recommended Action: Analyze cause of Machine Check using diag's and EFI tools.
WBEM EventID: 292. WBEM ProviderName: FPL_IndicationProvider.Error5152
Error in temporary mdt area. Probable Cause: The memory area where the MDT is
supposed to be built has an error in it, so the MDT cannot be built there.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 293. WBEM ProviderName: FPL_IndicationProvider.Error5155
Failed to find lmmio entry in mdt. Probable Cause: The MDT table is bad because it
did not have an LMMIO entry in it. Recommended Action: Reboot, if problem persists
contact your HP representative for support. WBEM EventID: 294. WBEM
ProviderName: FPL_IndicationProvider.Error5156
Memory page zero bad. Probable Cause: Memory page 0 was slated for deallocation
in the PDT. Recommended Action: FW is written such that this event should never
be generated. If the user sees this event, please contact HP support. WBEM EventID:
295. WBEM ProviderName: FPL_IndicationProvider.Error5157
Failed to find space in mdt. Probable Cause: FW requested an entry in the MDT, and
there wasn't a large enough chunk of contiguous memory for the requested size.
Recommended Action: Reboot, if problem persists contact your HP representative
for support. WBEM EventID: 296. WBEM ProviderName: FPL_IndicationProvider.Error5158
Media failure: info was not retrieved/logged. Probable Cause: The Error handler has
failed to retrieve or log data due to a media failure. Recommended Action: Reboot
if necessary, if problem persists contact your HP representative for support. WBEM
EventID: 297. WBEM ProviderName: FPL_IndicationProvider.Warning5159
Bus interface register test failed. Probable Cause: The CEC failed the register test.
Recommended Action: Contact HP support to troubleshoot the problem. WBEM
EventID: 298. WBEM ProviderName: FPL_IndicationProvider.Warning5160
Memory ECC normal write/read test failed. Probable Cause: The DIMM that maps
to address 0 is not seated properly. Recommended Action: Check all of the DIMMs
in the system and make sure that they are inserted fully into the slot with the retention
mechanism in place. WBEM EventID: 299. WBEM ProviderName:
FPL_IndicationProvider.Warning5161
DIMM loading order error: DIMM deallocated. Probable Cause: A required DIMM
is not loaded in order to allow for proper operation of the DIMM specified in the
physical location. Recommended Action: Refer to the user's manual for Memory
loading instructions. WBEM EventID: 300. WBEM ProviderName:
FPL_IndicationProvider.Warning5171
DIMM SPD checksum failed. Probable Cause: The DIMMs SPD EEPROM got
corrupted. Recommended Action: Contact HP Support personnel to troubleshoot
the problem. WBEM EventID: 301. WBEM ProviderName: FPL_IndicationProvider.Warning5172
Platform Events 19