HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
Memory interleaving algorithm failed. Probable Cause: Unspecified. WBEM EventID:
2903. WBEM ProviderName: FPL_IndicationProvider.Error5199
Memory interleave generation failed. Probable Cause: DIMM(s) that map into low
memory have errors on them. Recommended Action: Contact HP support to
troubleshoot the problem. WBEM EventID: 318. WBEM ProviderName:
FPL_IndicationProvider.Error5202
Uncorrectable (multiple-bit) ECC error in DIMM. Probable Cause: Multiple bit error
in DIMM. Recommended Action: Contact HP Support personnel to troubleshoot the
problem. WBEM EventID: 2451. WBEM ProviderName: FPL_IndicationProvider.Warning5204
Memory register test failed. Probable Cause: Internal SFW error. Recommended
Action: Update to most recent SFW. WBEM EventID: 319. WBEM ProviderName:
FPL_IndicationProvider.Warning5205
SPD found no memory DIMMs. Probable Cause: No DIMMs were detected.
Recommended Action: Install DIMMs or Contact HP Support personnel to
troubleshoot the problem. WBEM EventID: 320. WBEM ProviderName:
FPL_IndicationProvider.Error5208
No memory found. Probable Cause: FW found memory, but it could not find a
correctly loaded rank. Recommended Action: Before this event is sent, FW will output
which ranks it is deallocating and why. Review the preceding events and refer to the
users manual to correct the memory loading. WBEM EventID: 321. WBEM
ProviderName: FPL_IndicationProvider.Error5209
Cannot log memory error because PDT is disabled. Probable Cause: FW found
memory errors during selftest, but could not deallocate the page because the PDT is
disabled. Recommended Action: Re-enable the PDT by clearing NVM. WBEM
EventID: 322. WBEM ProviderName: FPL_IndicationProvider.Error5211
PDT is disabled. Probable Cause: Informational event indicating that FW will not
use the PDT this boot. Recommended Action: No action is needed if user does not
want to use the PDT, otherwise, clear NVM. WBEM EventID: 323. WBEM
ProviderName: FPL_IndicationProvider.Warning5212
Error adding entry to PDT. Probable Cause: NVM write error. Recommended Action:
Contact HP support personnel to troubleshoot the problem. WBEM EventID: 324.
WBEM ProviderName: FPL_IndicationProvider.Warning5214
Cannot add PDT entry-PDT full. Probable Cause: An attempt was made to add an
entry to a full PDT. Recommended Action: Run the 'pdt' command from the EFI shell
and remove/replace the DIMM that has the most PDT entries. If that doesn't work,
contact HP support. WBEM EventID: 1744. WBEM ProviderName:
FPL_IndicationProvider.Error5216
Memory platform data update failure. Probable Cause: Memory FW was unable to
save or restore the original error configuration. Recommended Action: If this is seen,
update SFW. WBEM EventID: 326. WBEM ProviderName: FPL_IndicationProvider.Warning5218
Can't find memory rank entry. Probable Cause: The rank structure that corresponds
to the rankID in the data field could not be found in the Rank table, possibly due to
NVM corruption. Recommended Action: Contact HP support to troubleshoot the
problem. WBEM EventID: 327. WBEM ProviderName: FPL_IndicationProvider.Warning5219
Memory error overflow:. Probable Cause: An error other than a memory error
occurred during the memory test. Recommended Action: Contact HP support to
troubleshoot the problem. WBEM EventID: 329. WBEM ProviderName:
FPL_IndicationProvider.Warning5237
Memory forward progress code invalid. Probable Cause: The forward progress bits
are invalid. Recommended Action: Upgrade to latest system firmware, or contact
HP support to troubleshoot the problem. WBEM EventID: 330. WBEM ProviderName:
FPL_IndicationProvider.Warning5238
Platform Events 21