HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
Memory error status invalid. Probable Cause: Non-memory errors were detected
during the memory test that FW doesn't know how to handle. Recommended Action:
Update to the latest SFW. Recommended Action: Contact HP support to troubleshoot
the problem. WBEM EventID: 331. WBEM ProviderName: FPL_IndicationProvider.Warning5244
Memory error summary bits invalid. Probable Cause: The memory test summary
word is invalid. Recommended Action: Update to the latest SFW. Recommended
Action: Contact HP support to troubleshoot the problem. WBEM EventID: 332. WBEM
ProviderName: FPL_IndicationProvider.Warning5245
Unexpected machine check during memory code. Probable Cause: Incompatible
memory controller and memory DIMM. Recommended Action: Update system board
with current memory controller. WBEM EventID: 2685. WBEM ProviderName:
FPL_IndicationProvider.Error5248
Serial Presence Detect (SPD) has been skipped. Probable Cause: Control bit to skip
DIMM SPD check is set. Recommended Action: Clear NVM. Recommended Action:
Update PDC. Recommended Action: Contact HP support to troubleshoot the problem.
WBEM EventID: 337. WBEM ProviderName: FPL_IndicationProvider.Warning5256
An Alternate Memory Config has been loaded into the system. Probable Cause:
Control bit to use an alternate memory config are set. Recommended Action: Clear
NVM Update SFW Contact HP support to troubleshoot the problem. WBEM EventID:
338. WBEM ProviderName: FPL_IndicationProvider.Warning5257
Nested Machine Checks. Probable Cause: A second machine check occurred while
the system was processing a machine check. Recommended Action: If automated
analysis has not occurred, use diagnostics or the MCA analyzer to determine the
cause. WBEM EventID: 8337. WBEM ProviderName: FPL_IndicationProvider.Error5258
OS INIT address not registered. Probable Cause: The OS has not registered an OS_INIT
vector. Recommended Action: No action is required. The OS has failed to register
the vector or has chosen not to. WBEM EventID: 340. WBEM ProviderName:
FPL_IndicationProvider.Warning5260
OS MCA address not registered. Probable Cause: The OS has not registered an
OS_MCA vector. Recommended Action: None, the OS has failed to register the vector
or has chosen not to. WBEM EventID: 341. WBEM ProviderName:
FPL_IndicationProvider.Warning5263
OS MCA did not correct the Machine Check. Probable Cause: Uncorrected Machine
Check. Recommended Action: Analyze cause of Machine Check using diagnostic
and EFI tools. WBEM EventID: 342. WBEM ProviderName: FPL_IndicationProvider.Warning5264
Found bad miscellaneous register. Probable Cause: A PDH register has failed.
Recommended Action: Reboot if necessary, if problem persists contact your HP
representative for support. WBEM EventID: 343. WBEM ProviderName:
FPL_IndicationProvider.Error5266
SAL_CHECK failed for an unknown reason. Probable Cause: The handler for
SAL_CHECK has failed for an unknown reason. Recommended Action: Reboot if
necessary, if problem persists contact your HP representative for support. WBEM
EventID: 344. WBEM ProviderName: FPL_IndicationProvider.Warning5268
SAL_INIT failed for an unknown reason. Probable Cause: The handler for SAL_INIT
has failed for an unknown reason. Recommended Action: Reboot if necessary, if
problem persists contact your HP representative for support. WBEM EventID: 345.
WBEM ProviderName: FPL_IndicationProvider.Warning5270
Unspecified memory interleave error. Probable Cause: FW encountered a fatal
interleaving error. Recommended Action: Update SFW. Recommended Action:
Contact HP support to troubleshoot the problem. WBEM EventID: 346. WBEM
ProviderName: FPL_IndicationProvider.Warning5278
22 WBEM Provider Event Tables