HP Insight Management WBEM Provider Events Reference Guide

Event DescriptionEvent
Severity
Event ID
EFI detected invalid internal privilege level. Probable Cause: Invalid argument with
EFI. Recommended Action: Upgrade system firmware. If problem persists, contact
HP support to troubleshoot the problem. WBEM EventID: 522. WBEM ProviderName:
FPL_IndicationProvider.Warning5786
EFI detected invalid privilege level when setting password. Probable Cause: Internal
EFI error. Recommended Action: Upgrade system firmware. If problem persists,
contact HP support to troubleshoot the problem. WBEM EventID: 523. WBEM
ProviderName: FPL_IndicationProvider.Warning5787
EFI MDT table is bad. Probable Cause: SFW has determined that the MDT table is
invalid. Recommended Action: Reboot or update System FW. If problem persists
contact your HP representative for support. WBEM EventID: 524. WBEM
ProviderName: FPL_IndicationProvider.Error5788
Processor has incompatible fixed core ratio. Probable Cause: A CPU has a fixed ratio
that is incompatible with the FSB frequency set in the chipset. Recommended Action:
Contact your HP representative for support. WBEM EventID: 525. WBEM
ProviderName: FPL_IndicationProvider.Warning5790
All processors slated for compatibility deconfiguration. Probable Cause: The user or
SFW has set all CPUs to be deconfigured. Recommended Action: Look for events
indicating incompatible or bad CPUs and replace them. If problem persists contact
your HP representative for support. WBEM EventID: 526. WBEM ProviderName:
FPL_IndicationProvider.Error5791
An unexpected or invalid value was read from a crossbar remote route table. Probable
Cause: An XBC is indicating a port failure. Recommended Action: Validate all of the
cells connectivity to the PDCheck the XBC chips seating reset the system replace
either cells/system backplane. WBEM EventID: 527. WBEM ProviderName:
FPL_IndicationProvider.Error5793
Error reading the PORT[n]_NEIGHBOR_INFO XBC CSR. Probable Cause: Possible
bad link, crossbar, or cell connection. Recommended Action: Check crossbar and link
specified in the event data. Reset cell. WBEM EventID: 528. WBEM ProviderName:
FPL_IndicationProvider.Error5794
memory DIMM quad mis-match. Probable Cause: The user installed a mismatched
quad of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width).
Recommended Action: Install memory ranks in quads of DIMMs that are the same
size and DRAM width. WBEM EventID: 529. WBEM ProviderName:
FPL_IndicationProvider.Warning5795
Firmware detected excessive errors on the DIMM. Probable Cause: Firmware detected
excessive errors on the DIMM / Replace the specified DIMM. WBEM EventID: 530.
WBEM ProviderName: FPL_IndicationProvider.Warning5796
The OE (output enable) bit was not set for a XBC port. Probable Cause: Possible
firmware or link error. Recommended Action: Check XBC and port specified by event
data. WBEM EventID: 531. WBEM ProviderName: FPL_IndicationProvider.Error5797
An error occurred while trying to read the PORT_STATUS CSR for a XBC port.
Probable Cause: Possible bad connection between cell and backplane. Recommended
Action: Check for hardware errors. Reset cell. WBEM EventID: 532. WBEM
ProviderName: FPL_IndicationProvider.Error5798
A XBC port was unexpectedly found to be landmined. Probable Cause: No action
required. WBEM EventID: 533. WBEM ProviderName: FPL_IndicationProvider.Error5799
CPUs running at different speeds were detected during rendezvous. Probable Cause:
Reconfigure the PD so that all cells have processors running at the same speed. WBEM
EventID: 1016. WBEM ProviderName: FPL_IndicationProvider.Error5800
Platform Events 37