Read command on System Backplane I2C bus failed. Probable Cause: The 100 pin
cable from the Utilities Backplane to the System Backplane is bad, or is not properly
connected. Recommended Action: Check and reseat the System Backplane Utilities
cable. If no help, replace the System Backplane utilities cable following the Backplane
Utilities Cable Remove and Replace procedures. WBEM EventID: 697. WBEM
ProviderName: FPL_IndicationProvider.Warning7877
Write command on System Backplane I2C bus failed. Probable Cause: The 100 pin
cable from the Utilities Backplane to the System Backplane is bad, or is not properly
connected. Recommended Action: Check and reseat the System Backplane Utilities
cable. If no help, replace the System Backplane utilities cable following the Backplane
Utilities Cable Remove and Replace procedures. WBEM EventID: 698. WBEM
ProviderName: FPL_IndicationProvider.Warning7878
System Backplane Power Fault. Probable Cause: While running normally, the CLU
microcontroller detected a fault on the I2C Bus from the system Backplane LPM.
Recommended Action: Check other log entries around this time for other events. If
there are other events, analyze for best troubleshooting approach. Check the log
carefully as a shorted ASIC could cause many errors to occur. These errors will not
necessarily point to the ASIC. If none, replace failed Backplane Power Board. WBEM
EventID: 699. WBEM ProviderName: FPL_IndicationProvider.Error7879
System Backplane voltage margin failed. Probable Cause: The CLU was unable to
write to the voltage margin register on the System backplane. Recommended Action:
Try re-margining the system backplane and check connections. If many I2C access
events are occurring inspect the UGUY utilities board. WBEM EventID: 700. WBEM
ProviderName: FPL_IndicationProvider.Error7880
Failure to write data to FRUID EEPROM. Probable Cause: The entity being written
to is not powered up. Recommended Action: Power the entity with the PE command.
WBEM EventID: 701. WBEM ProviderName: FPL_IndicationProvider.Warning7891
CPU fan failed. Probable Cause: The CPU fan identified by the attached physical
location has failed. Recommended Action: Contact HP Support personnel to
troubleshoot problem. WBEM EventID: 2904. WBEM ProviderName:
FPL_IndicationProvider.Error7892
CPU fan failing. Probable Cause: The CPU fan identified by the attached physical
location is not operating at expected speed. Recommended Action: Contact HP
Support personnel to troubleshoot problem. WBEM EventID: 2905. WBEM
ProviderName: FPL_IndicationProvider.Warning7893
CC chip fan failed. Probable Cause: The CC chip fan identified by the attached physical
location has failed. Recommended Action: Contact HP Support personnel to
troubleshoot problem. WBEM EventID: 2906. WBEM ProviderName:
FPL_IndicationProvider.Error7894
CC chip fan failing. Probable Cause: The CC chip fan identified by the attached
physical location is not operating at expected speed. Recommended Action: Contact
HP Support personnel to troubleshoot problem. WBEM EventID: 2907. WBEM
ProviderName: FPL_IndicationProvider.Warning7895
System FW and the PDHC have incompatible shared memory interface revisions.
Probable Cause: (Probable) Either System firmware or PDHC Firmware on the named
cell was upgraded to a new major revision number and not the other. The major
numbers must match when checked by the PDHC or else the cell will not be allowed
to boot. Recommended Action: Use FWUU (Firmware Update Utility) to check the
revision numbers of PDHC and PDC Firmware on the cell(s) called out in the event
log. Compare to other cells in the complex, or, if single cell, check firmware revs.
available to FWUU. WBEM EventID: 4954. WBEM ProviderName:
FPL_IndicationProvider.Error7896
PDH Controller firmware version is not supported with this version of MP FW.
Probable Cause: PDH Controller firmware version is not supported with this version
of MP FW. Recommended Action: Update PDHC or MP firmware. WBEM EventID:
707. WBEM ProviderName: FPL_IndicationProvider.Error7902