Cells trying to join a PD are at incompatible firmware revisions. Probable Cause: The
reporting cell is at a different firmware revision than the cell reported in the data
field. A PD cannot be established. Please reprogram the 2 cells to the same firmware
revision. WBEM EventID: 733. WBEM ProviderName: FPL_IndicationProvider.Error8207
An attempt to write to a device on the PM's I2C bus has failed. Probable Cause: A
hardware error has occurred. Recommended Action: Replace the UGUY board.
WBEM EventID: 734. WBEM ProviderName: FPL_IndicationProvider.Warning8212
An attempt to read from a device on the PM's I2C bus has failed. Probable Cause: A
hardware error has occurred. Recommended Action: Replace the UGUY board.
WBEM EventID: 735. WBEM ProviderName: FPL_IndicationProvider.Warning8214
An error was encountered updating the cell info structure in ICM. Probable Cause:
This should not happen. Contact engineering to diagnose the problem. WBEM
EventID: 736. WBEM ProviderName: FPL_IndicationProvider.Warning8216
An error was encountered pointing the slave cell consoles to the diva. Probable Cause:
A CPU on the slave cell could not process an interrupt in time or establish the diva
console. WBEM EventID: 737. WBEM ProviderName: FPL_IndicationProvider.Warning8218
An error was encountered trying to relocate a slave cells registry. Probable Cause:
There could be a PD rendezvous error or a processor on the slave cell failed to respond
to an interrupt in time. WBEM EventID: 738. WBEM ProviderName:
FPL_IndicationProvider.Error8219
Complex Profile Group C CRC didn't match the expected value. Probable Cause:
Push out a new Group C complex profile. WBEM EventID: 2441. WBEM
ProviderName: FPL_IndicationProvider.Error8220
Failure to identify a core cell during Global MCA. Probable Cause: This will lead to
a system reset. WBEM EventID: 1034. WBEM ProviderName: FPL_IndicationProvider.Error8238
Internal firmware programming error in the PMI handler. Probable Cause: Report
the IP to the firmware team. Reset the system. This cannot be worked around in the
field. WBEM EventID: 743. WBEM ProviderName: FPL_IndicationProvider.Error8240
During a Cell On Line Add inconsistent number of cells discovered. Probable Cause:
This can be caused by inconsistent profile information. This can also occur when an
expected cell did not make the original boot of the partition. Update the complex
profile to all the cells with a correct view of the system and try to add the cell again.
WBEM EventID: 744. WBEM ProviderName: FPL_IndicationProvider.Error8243
CPUs of different maximum core frequencies are installed. Probable Cause: CPU's
of mixed maximum core frequencies are installed. Recommended Action: Install
CPU's with the same speed and cache size. WBEM EventID: 753. WBEM
ProviderName: FPL_IndicationProvider.Warning8269
The RVL CC-Togo link initialization workaround (PS221) failed. Probable Cause:
Hardware link initialization failed. Recommended Action: Contact HP support. Reset
cell. WBEM EventID: 2466. WBEM ProviderName: FPL_IndicationProvider.Error8271
Internal firmware programming error. Probable Cause: Report the IP to the firmware
team. Reset the system. This cannot be worked around in the field. WBEM EventID:
760. WBEM ProviderName: FPL_IndicationProvider.Error8652
Initialization of a PCI node in the firmware device tree failed. Probable Cause: The
PCI component could not create a device tree node. Recommended Action: This is
an internal system firmware error. Update system firmware or contact a system
firmware representative. WBEM EventID: 774. WBEM ProviderName:
FPL_IndicationProvider.Warning8690
An error was encountered while scanning the PCI bus. Probable Cause: The PCI
component experienced an internal system firmware error while scanning the PCI
bus. Recommended Action: This is an internal system firmware error. Update system
firmware or contact a system firmware representative. WBEM EventID: 775. WBEM
ProviderName: FPL_IndicationProvider.Error8691