CPU Dual Core Initialization Failed. Probable Cause: MX2 initialization failed.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 918. WBEM ProviderName: FPL_IndicationProvider.Warning9379
Second CPU in Pair has been disabled. Probable Cause: The second CPU in the Dual
Core has been deconfigured as a result of the first core being deconfigured.
Recommended Action: Investigate the cause of the first core being deconfigured.
WBEM EventID: 919. WBEM ProviderName: FPL_IndicationProvider.Warning9380
Virtualzing Dual Core Registers Failed. Probable Cause: FW failed to virtualize the
mx2 interposer. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 920. WBEM ProviderName:
FPL_IndicationProvider.Error9382
Virtualizing Dual Core Interposer has failed. Probable Cause: Virtualizing the Dual
Core Interposer has failed. Recommended Action: Reboot. If problem persists contact
your HP representative for support. WBEM EventID: 921. WBEM ProviderName:
FPL_IndicationProvider.Warning9383
Install PMI Handler Failed. Probable Cause: Installation of the FW PMI handler has
failed. Recommended Action: Reboot. If problem persists contact your HP
representative for support. WBEM EventID: 922. WBEM ProviderName:
FPL_IndicationProvider.Error9385
Cell failed compatibility checks. Probable Cause: CPUs are incompatible with each
other. Recommended Action: Contact HP Support personnel to troubleshoot the
problem. WBEM EventID: 923. WBEM ProviderName: FPL_IndicationProvider.Error9388
PDH space not available after release from reset. Probable Cause: A hardware fault
has occurred. Recommended Action: Contact HP Support personnel to troubleshoot
the Cell Board, Cell Power Board and PDH Daughtercard. WBEM EventID: 924.
WBEM ProviderName: FPL_IndicationProvider.Error9389
MPON failed to release. Probable Cause: A hardware fault has occurred.
Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board,
Cell Power Board and PDH Daughtercard. WBEM EventID: 925. WBEM
ProviderName: FPL_IndicationProvider.Error9390
Dillon failed to reset. Probable Cause: Hardware failure. Recommended Action: Fix
the hardware, pdh riser or cell. WBEM EventID: 926. WBEM ProviderName:
FPL_IndicationProvider.Error9391
DMD clock is not running. Probable Cause: A hardware fault has occurred.
Recommended Action: Contact HP Support personnel to troubleshoot the Cell Board,
Cell Power Board and PDH Daughtercard. WBEM EventID: 927. WBEM
ProviderName: FPL_IndicationProvider.Error9392
All cpus on the Cell are scheduled to be deconfigured. Probable Cause: All cpus on
the cell have been scheduled for deconfiguration. On the next reset, the cell will no
longer be operational; system firmware will deconfigure all the cpus and this cell
will not be part of a partition. This action is not recommended. To recover, the
NVRAM on the PDH card must be cleared, the cell power cycled, and defaults
restored from disk. WBEM EventID: 928. WBEM ProviderName:
FPL_IndicationProvider.Error9394
Power has been removed from AC input A0. Probable Cause: A power source has
been removed from the chassis. WBEM EventID: 931. WBEM ProviderName:
FPL_IndicationProvider.Warning9417
Power has been removed from AC input A1. Probable Cause: A power source has
been removed from the chassis. WBEM EventID: 932. WBEM ProviderName:
FPL_IndicationProvider.Warning9418
Power has been removed from AC input B0. Probable Cause: A power source has
been removed from the chassis. WBEM EventID: 933. WBEM ProviderName:
FPL_IndicationProvider.Warning9419
Power has been removed from AC input B1. Probable Cause: A power source has
been removed from the chassis. WBEM EventID: 934. WBEM ProviderName:
FPL_IndicationProvider.Warning9420