HP Insight Management WBEM Provider Events Reference Guide

A Cell-Cell link is connected to an unexpected cell. Data field: expected neighbor ID
| (actual neighbor ID 16) | (target cell 32) | (local cell 48). Probable Cause: System
firmware found a discrepancy in the expected system topology. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 2950. WBEM ProviderName:
FPL_IndicationProvider.Warning10409
An EFI driver failed to load. Probable Cause: A reflashable EFI Driver has failed a
checksum test. Recommended Action: Reflash the system firmware to correct this
error. WBEM EventID: 6852. WBEM ProviderName: FPL_IndicationProvider.Warning10412
VM_FindAllRoutes returned an unexpected error during Non-Coherent table setup.
Data field: (return value) | (source cell 32) | (target cell 48). Probable Cause: Internal
firmware error or data corruption. Recommended Action: Capture IPMI event logs,
look for additional errors. Contact your HP Support Representative to analyze the
fabric. WBEM EventID: 2951. WBEM ProviderName: FPL_IndicationProvider.Warning10413
In SetupNCTable, a write to the GLOBAL_LINK_SEL_NONCOH CSR failed. Data
field: (data written to CSR) | (actual CSR data read 32). Probable Cause: System
firmware was unable to write a fabric hardware register. Recommended Action:
Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 2952. WBEM ProviderName:
FPL_IndicationProvider.Warning10414
SetupNCTable failed in ArfPhase3. Data field: cell set passed in to SetupNCTable.
Probable Cause: System firmware was unable to write some fabric hardware registers.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2953. WBEM
ProviderName: FPL_IndicationProvider.Warning10415
A failure occurred while prepping a back-to-back system for post-rendezvous Arches
Fabric setup. Data field: return value from Phase4BackToBackPrep. Probable Cause:
System firmware was unable to write various fabric hardware registers.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 2954. WBEM
ProviderName: FPL_IndicationProvider.Warning10427
ArfPhase4 was unable to set up the Non-Coherent link select to at least one cell in
its alive/gsm sharing set. Data field: bitmap of unreachable cells. Probable Cause:
System firmware was unable to find valid routes to each cell in a previously good
partition. Possible cable/connection problems. Recommended Action: Capture IPMI
event logs, look for additional errors. Contact your HP Support Representative to
analyze the fabric. WBEM EventID: 2955. WBEM ProviderName:
FPL_IndicationProvider.Warning10429
Unable to set the Non-Coherent route. Data field: (sourceCell 32) | (cell set passed
in to SetupNCTable). Probable Cause: System firmware was unable to write various
fabric hardware registers. Recommended Action: Capture IPMI event logs, look for
additional errors. Contact your HP Support Representative to analyze the fabric.
WBEM EventID: 2956. WBEM ProviderName: FPL_IndicationProvider.Warning10431
Unable to setup the Coherent route table for a cell in our partition. Data field:
(sourceCell 32) | (cell set passed in to SetupCohTable). Probable Cause: System
firmware was unable to write various fabric hardware registers. Recommended
Action: Capture IPMI event logs, look for additional errors. Contact your HP Support
Representative to analyze the fabric. WBEM EventID: 2957. WBEM ProviderName:
FPL_IndicationProvider.Warning10432
Error writing the XBC ROUTE_TABLE_ENABLE_MASK CSR. Data field: (route set
to disable) | (xbcNum 32) | (xbc port 48). Probable Cause: System firmware was
unable to write various fabric hardware registers. Recommended Action: Capture
IPMI event logs, look for additional errors. Contact your HP Support Representative
to analyze the fabric. WBEM EventID: 2958. WBEM ProviderName:
FPL_IndicationProvider.Warning10435
Platform Events 63