HP Insight Management WBEM Provider Events Reference Guide

Failed to open a fabric link. Probable Cause: System Firmware was unable to open
the crossbar link. Recommended Action: Collect IPMI Event Logs. Contact your HP
Support Representative to analyze the fabric. WBEM EventID: 4895. WBEM
ProviderName: FPL_IndicationProvider.Warning10559
Error when writing the XBC return route. Probable Cause: write to XBC failed.
Recommended Action: Contact HP Support personnel to check the XBC. WBEM
EventID: 4897. WBEM ProviderName: FPL_IndicationProvider.Warning10560
Error enabling the XBC return route. Probable Cause: write to XBC failed.
Recommended Action: Contact HP Support personnel to check the XBC. WBEM
EventID: 4896. WBEM ProviderName: FPL_IndicationProvider.Warning10561
Failed to disperse the routes across links. Probable Cause: System Firmware was
unable to route the crossbar fabric. Recommended Action: Collect IPMI Event logs.
Contact your HP Support Representative to troubleshoot the fabric and/or backplane
subsystem. WBEM EventID: 4894. WBEM ProviderName: FPL_IndicationProvider.Warning10564
Error setting up XBC-XBC link for routing across it. Probable Cause: System Firmware
was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event
logs. Contact your HP Support Representative to troubleshoot the fabric and/or
backplane subsystem. WBEM EventID: 4899. WBEM ProviderName:
FPL_IndicationProvider.Warning10565
Error while routing the remote side of a route. Probable Cause: System Firmware
was unable to route the crossbar fabric. Recommended Action: Collect IPMI Event
logs. Contact your HP Support Representative to troubleshoot the fabric and/or
backplane subsystem. WBEM EventID: 4898. WBEM ProviderName:
FPL_IndicationProvider.Warning10566
Error getting address while routing the remote XBC. Probable Cause: Failed to get
a fabric address. Recommended Action: Look for additional IPMI event logs. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 4886. WBEM
ProviderName: FPL_IndicationProvider.Warning10567
Error getting the neighbor info. Probable Cause: XBC register read failure.
Recommended Action: Contact HP Support personnel to analyze the crossbar chip.
WBEM EventID: 4887. WBEM ProviderName: FPL_IndicationProvider.Warning10568
Error finding the shortest route. Probable Cause: System Firmware encountered a
problem while processing the crossbar fabric graphs. Recommended Action: Collect
IPMI event logs. Contact your HP Support Representative to analyze the fabric.
WBEM EventID: 4888. WBEM ProviderName: FPL_IndicationProvider.Warning10569
Error writing the remote XBC routing register. Probable Cause: write to XBC failed.
Recommended Action: Contact HP Support personnel to check the XBC. WBEM
EventID: 4889. WBEM ProviderName: FPL_IndicationProvider.Warning10570
Error enabling the routes on the remote XBC. Probable Cause: write to XBC failed.
Recommended Action: Contact HP Support personnel to check the XBC. WBEM
EventID: 4890. WBEM ProviderName: FPL_IndicationProvider.Warning10571
Error writing the routing register on the local XBC. Probable Cause: write to XBC
failed. Recommended Action: Contact HP Support personnel to check the XBC.
WBEM EventID: 4891. WBEM ProviderName: FPL_IndicationProvider.Warning10572
Error writing the local XBC routing registers to reach a remote cell. Probable Cause:
write to XBC failed. Recommended Action: Contact HP Support personnel to check
the XBC. WBEM EventID: 4892. WBEM ProviderName: FPL_IndicationProvider.Warning10573
Error enabling the local XBC routes. Probable Cause: write to XBC failed.
Recommended Action: Contact HP Support personnel to check the XBC. WBEM
EventID: 4893. WBEM ProviderName: FPL_IndicationProvider.Warning10574
SynchGraphs() failed during Arches Fabric Phase 4. Data field: return value from
SynchGraphs(). Probable Cause: Internal firmware error or data corruption.
Recommended Action: Capture IPMI event logs, look for additional errors. Contact
your HP Support Representative to analyze the fabric. WBEM EventID: 4524. WBEM
ProviderName: FPL_IndicationProvider.Warning10617
66 WBEM Provider Event Tables