HP Insight Management WBEM Provider Events Reference Guide

fPars PMI handler was unable to Notify a CPU's new owner after a migrate. Probable
Cause: OS incorrectly set up the IOSAPIC redirection entry through the FSHWA
interface. Recommended Action: Contact HP support. WBEM EventID: 6702. WBEM
ProviderName: FPL_IndicationProvider.Warning12208
An OS is shutting down due to an MCA (Machine Check Abort) or INIT. Probable
Cause: An MCA or INIT occurred. Recommended Action: Analyze the dump + logs
for cause. If necessary contact HP Support for assistance. WBEM EventID: 6772.
WBEM ProviderName: FPL_IndicationProvider.Error12217
An OS is shutting down due to a panic. Probable Cause: An OS has panicked.
Recommended Action: Analyze the dump + logs for cause. If necessary contact HP
Support for assistance. WBEM EventID: 6773. WBEM ProviderName:
FPL_IndicationProvider.Error12218
An instance of CLU FW has an installed firmware revision that is incompatible with
the system type. Many system operations will fail until this condition is resolved.
Probable Cause: Following an in-the-box system type upgrade, or after a UGUY
board was replaced, the CLU FW may not have been updated to an appropriate
revision for the system type. Recommended Action: Contact your HP Customer
Support Representative to update all firmware entities to revisions that are appropriate
for the system type. WBEM EventID: 6771. WBEM ProviderName:
FPL_IndicationProvider.Error12222
The online diagnostics have identified a hardware problem. Probable Cause: OS
based diagnostics discovered a hardware problem. Recommended Action: Consult
the OS diagnostics logs for details about the problem. WBEM EventID: 6779. WBEM
ProviderName: FPL_IndicationProvider.Error12227
Over-Temperature or power condition detected for processor. Probable Cause: The
processor temperature or power has exceeded normal limits. The Enhanced Thermal
Management (ETM) feature of the processor has been employed to reduce the chip
power to allow operation within normal limits. If this condition persists, this will
have an adverse impact on the performance of this processor. Recommended Action:
Check that there are no issues with the cooling, and if the problem persists contact
HP service. WBEM EventID: 6836. WBEM ProviderName: FPL_IndicationProvider.Warning12228
An error occurred while checking the fabricless boot state. Probable Cause: System
firmware was unable to access the fabric graph or the expected vertex was not found.
Recommended Action: This is a symptom of a problem, not the cause. Look for
additional IPMI event logs that more accurately describe the problem. Contact your
HP Support Representative to investigate the fabric. WBEM EventID: 6775. WBEM
ProviderName: FPL_IndicationProvider.Warning12229
System firmware was unable to clear the link error masks. Probable Cause: This event
does not indicate the original cause. This is a problem encountered while handling
a fabric link error. Recommended Action: Collect IPMI event logs to determine the
original cause of the error. Contact your HP Support Representative to troubleshoot
the fabric. WBEM EventID: 6776. WBEM ProviderName: FPL_IndicationProvider.Warning12230
System firmware could not determine a link's address. Probable Cause: This event
does not indicate the original cause. This is a problem encountered while handling
a fabric link error. Recommended Action: Collect IPMI event logs to determine the
original cause of the error. Contact your HP Support Representative to troubleshoot
the fabric. WBEM EventID: 6777. WBEM ProviderName: FPL_IndicationProvider.Warning12231
System firmware was unable to turn a bad link off. Probable Cause: This event does
not indicate the original cause. This is a problem encountered while handling a fabric
link error. Recommended Action: Collect IPMI event logs to determine the original
cause of the error. Contact your HP Support Representative to troubleshoot the fabric.
WBEM EventID: 6778. WBEM ProviderName: FPL_IndicationProvider.Warning12232
84 WBEM Provider Event Tables