HP Insight Management WBEM Provider Events Reference Guide

A failure has occurred while attempting to update the FPGA ROM. Probable Cause:
Something has interfered with firmware update while it attempted to update the bits
in the FPGA ROM. Recommended Action: Do not remove power from the system.
Do not reset iLO. Attempt the update again. WBEM EventID: 8512. WBEM
ProviderName: FPL_IndicationProvider.Error13982
A failure has occurred while attempting to update the Power Monitor PIC. Probable
Cause: Something has interfered with firmware update while it attempted to update
the bits in the Power Monitor PIC. Recommended Action: Attempt the update again.
If this fails try resetting iLO or removing stand by power and attempt the update
again. WBEM EventID: 8513. WBEM ProviderName: FPL_IndicationProvider.Error13983
The system has been placed in security override mode. Probable Cause: A user has
asserted the physical presence button for a duration greater than 8 seconds and less
than 12 seconds. Recommended Action: This mode will timeout in 15 minutes or
less. To manually exit this mode go to the Access Settings web page. You can also
press the physical presence button for less than 4 seconds to reset iLO and clear this
mode. WBEM EventID: 8515. WBEM ProviderName: FPL_IndicationProvider.Error13984
The system is entering TPM physical presence mode. Probable Cause: A user has
asserted the TPM physical presence button for a duration of greater than 4 seconds
and less than 8 seconds. Recommended Action: No action is required. This event
indicates that the system was placed in a mode where restricted commands can now
be executed by the TPM. Asserting the physical presence button for less than 4 seconds
will reset iLO and clear the TPM physical presence mode. WBEM EventID: 8516.
WBEM ProviderName: FPL_IndicationProvider.Error13986
The TPM did not accept the start-up request. Probable Cause: The TPM can be
defective or has detected a tampering attempt. Recommended Action: Verify for
possible tampering. Replace the board hosting the TPM chip. WBEM EventID: 8517.
WBEM ProviderName: FPL_IndicationProvider.Error13993
The thread has received an interruption during boot. Probable Cause: Firmware, EFI
applications, OS boot, or Hardware Errors caused unexpected interruptions.
Recommended Action: Review the following interruption events in the FPL. Reboot
the system. If problem persists, contact support. WBEM EventID: 8519. WBEM
ProviderName: FPL_IndicationProvider.Error14002
Fans are entering blowout mode. Probable Cause: A sensor may have been unreadable
or the lid to the system may be detected as open. See the datafield for the sensor that
caused the error forcing fans into blowout mode. Recommended Action: Investigate
the sensor implicated in the datafield to determine the cause of failure. If a temp
sensor can't be read try AC cycling the box; if a fan sensor can't be read try reseating
the fan and AC cycling the box; if the lid latch is detected as open, place lid on the
box, or if it is already there; reseat it. If none of this helps try replacing the FRU
associated with sensor. WBEM EventID: 9071. WBEM ProviderName:
FPL_IndicationProvider.Warning14051
Core Analysis Engine DB threw an exception. WBEM EventID: 10444. WBEM
ProviderName: FPL_IndicationProvider.Warning14190
A Socket Monarch Thread has stopped making forward progress. Probable Cause:
Unexpected Firmware or Hardware Errors. Recommended Action: Verify that the
firmware is at the current supported revision. Replace the processor. WBEM EventID:
9867. WBEM ProviderName: FPL_IndicationProvider.Error14219
The Partition Monarch Thread has stopped making forward progress. Probable
Cause: Unexpected Firmware or Hardware Errors. Recommended Action: Verify
that the firmware is at the current supported revision. Replace the processor. WBEM
EventID: 9868. WBEM ProviderName: FPL_IndicationProvider.Error14220
The processor module that contains the Monarch Thread was deconfigured. Probable
Cause: Unexpected Firmware or Hardware Error has been encountered.
Recommended Action: Verify that the system is at the current supported revision.
Replace the processor. WBEM EventID: 9869. WBEM ProviderName:
FPL_IndicationProvider.Error14221
Core Analysis Engine failed to get SAL error data. WBEM EventID: 10445. WBEM
ProviderName: FPL_IndicationProvider.Warning14321
Platform Events 95