SmartSetup Scripting Toolkit Administrator's Guide

Table Of Contents
Table 4 hpacuscripting Error Codes (continued)
ReasonMessageWarning
Code
The script file specifies a logical drive ID that is not the first unused
ID in the sequence. For example, if the controller has only Logical
Drive 1 and the script file attempts to create Logical Drive 3
(without Logical Drive 2), the script generates this error. This error
can occur when using an input file with logical drive numbers that
are not sequential. In this case, you must change the logical drive
numbers so that they are sequential in the input file.
New Logical Drive ID does
not match the next available
Logical Drive ID
If you are attempting to
replicate a configuration
that has non-consecutive
logical drive numbers, then
you must change the script
file so that the logical
drive numbers are
consecutive.
2836
When running in Configure mode, this error occurs when the
Logical Drive ID in the script file already exists in the configuration.
Configure mode can only create new logical drives.
New Logical Drive ID already
exists
2837
The array has no free space, or the maximum number of logical
drives has already been reached.
Cannot create Logical Drive2838
The controller does not support RAID migration, or the current
controller configuration does not allow migration to occur.
Cannot migrate Logical Drive
RAID
2839
The controller does not support extension, or the current controller
configuration cannot be extended. For example, extension is not
possible if the array has no free space.
Cannot extend Logical Drive2841
The specified RAID is invalid or is not possible with the current
physical disk and aarray configuration.
Invalid RAID2842
The specified size is invalid or is not possible with the current
configuration.
Invalid Size2843
The specified stripe size is invalid, not supported with the current
RAID level, or not supported with the current configuration.
Invalid Stripe Size2844
The valid parameters are Yes and No (default).Invalid
ClearConfigurationWithDataLoss
parameter
2849
The controller does not support setting a chassis name.Controller does not support
Chassis Name
2850
The entered chassis name is invalid. The chassis name can only
consist of the following characters: a-z, A-Z, 0-9, !, @, #, *, ( , )
, ,, - , _, +, :, ., /, and [space]. It cannot end with a space
character or exceed the maximum number of characters allowed
by the controller.
Invalid Chassis Name2851
The requested SSP state is not a valid SSP state.Invalid SSP State2852
The SSP settings cannot be changed for the controller or logical
drive.
Cannot change SSP settings2853
The adapter ID is not a valid adapter ID that was detected by the
controller.
Invalid SSP Adapter ID2854
Invalid Surface Scan Delay2857
The controller is not redundant or does not support redundancy
settings.
Controller does not support
redundancy settings
2861
The preferred path mode specified is not a valid preferred path
mode, or the controller is not available.
Invalid Preferred Path Mode2864
40 Utilities reference