HP Integrity rx2800 i2 Server User Service Guide

Log Entry 4: 01 Aug 2012 17:22:00
Alert Level 7: Fatal
Keyword: BOOT_NOT_DETECTED
No events were received from system firmware
Logged by: integrated Lights Out
Sensor: Processor
Data1: FRB2/Hang in POST failure
20501965B8020006 FFFF036F00070400
If the above Level 7 IPMI alert appears, verify the installation of your processor and if necessary
replace the processor.
7. If the processor is installed and functioning properly, check the SEL for the following IPMI event
after powering on the server to verify that POST has started.
NOTE: Your display might not exactly match the display shown.
Log Entry 3: 02 Aug 2012 11:28:16
Alert Level 2: Informational
Keyword: BOOT_START
CPU starting boot
Logged by: System Firmware located in socket 0,cpu 2,thread 0
Data: Major change in system state - Boot Start
5480006309E10005 0000000000000000
8. Check the SEL for any memory-related IPMI alerts.
NOTE: Your display might not exactly match the display shown.
Log Entry 1: 01 Aug 2012 17:20:38
Alert Level 5: Critical
Keyword: INSUFFICIENT_SYSTEM_MEMORY
This HW configuration does not have enough memory for the OS to boot.
Logged by: integrated Lights Out
Data: Data field unused
A080274200E10001 0000000000000000
Log Entry 11: 02 Aug 2012 11:28:38
Alert Level 7: Fatal
Keyword: MEM_NO_MEM_FOUND
No memory found
Logged by: System Firmware located in socket 0,cpu 2,thread 0
Data: Location - Blade (Blade Board)
E48000D109E10010 FFFFFFFFFFFFFF94
If either of the above IPMI alerts appear in the SEL, verify that the memory expansion board
and DIMMs are installed properly and if necessary, replace the memory expansion board
and DIMMs.
If any of the previous Level 5 or 7 IPMI alerts appear in the SEL after the processor, memory
expansion board and DIMMs have been replaced, then replace the system board.
84 Troubleshooting