HP Integrity rx2800 i2 Server User Service Guide

3. Extend or remove the server from the rack (“Removing the server from the rack” (page 106))
or “Extending the server from the rack” (page 102)).
4. Remove the access panel (“Removing the access panel” (page 50)).
5. Remove the PCI cage (“Removing the PCI riser cage” (page 51)).
6. Remove the necessary memory expansion boards (“Installing DIMMs” (page 56)).
7. Remove the power supply backplane.
To replace the component, reverse the removal procedure.
Removing and replacing the hard drive backplane
1. Power off the server (“Powering off the server” (page 106)).
2. Extend or remove the server from the rack (“Removing the server from the rack” (page 106))
or “Extending the server from the rack” (page 102)).
3. Remove the access panel (“Removing the access panel” (page 50)).
4. Remove all hot-plug hard drives (“Removing and replacing a hot-plug SAS hard drive” (page
111)).
5. Disconnect the SAS cable from the hard drive backplane.
Removing and replacing the hard drive backplane 117