HP Integrity rx2800 i2 Server User Service Guide
Removing and replacing a full-length expansion board
1. Power off the server (“Powering off the server” (page 106)).
2. Extend the server from the rack (“Extending the server from the rack” (page 102)).
3. Remove the access panel (“Removing and replacing the access panel” (page 113)).
4. Disconnect any external cables that are connected to the expansion board.
5. Remove the PCI riser cage (“Removing and replacing the PCI riser cage” (page 118)).
6. Disconnect any internal cables that are connected to the expansion board.
7. Remove the expansion board.
To replace the component, see “Installing expansion boards” (page 53).
Removing and replacing the cache module
NOTE: The cache module is required to enable the full feature firmware stack for RAID support,
and certain levels of RAID support also require the super capacitor module and a Advanced Pack
license key.
To enable Advanced Pack licensing, see “Adding a RAID Advanced Pack license key” (page 148).
1. Power off the server (“Powering off the server” (page 106)).
2. Extend or remove the server from the rack (“Removing the server from the rack” (page 106))
or “Extending the server from the rack” (page 102)).
3. Remove the access panel (“Removing and replacing the access panel” (page 113)).
4. Remove the PCI riser cage (“Removing and replacing the PCI riser cage” (page 118)).
5. Disconnect the cable to the super capacitor pack.
120 Removal and replacement procedures