HP Integrity rx2800 i2 Server User Service Guide

Table 31 Processor events that might illuminate SID LEDs (continued)
NotesSourceCauseSample IPMI EventsDiagnostic
LEDs
processor
(thread) has
timed out
SFWA logical slave
processor
Type E0h, 57d:26d
BOOT_INCOMPATIBLE_SLAVE
Processors
(thread) is
incompatible
with logical
monarch
processor
SFWProcessor PAL
incompatible
with processor
Type E0h, 56d:26d
BOOT_INCOMPATIBLE_ PAL
Processor
SFWA processor
failed
Type E0h, 34d:26d
BOOT_CPU_FAILED
Processors
SFWA logical
processor
Type E0h, 33d:26d
BOOT_CPU_EARLY_TEST_FAIL
Processors
(thread) failed
early self test
Possible
seating or
iLO MPNo physical
processor cores
present
Type 02h, 25h:71h:80h
MISSING_FRU_DEVICE
Processors
failed
processor
Troubleshooting the server memory
Memory DIMM load order
For a minimally loaded server, two equal-size DIMMs must be installed in the DIMM slots. For more
information, see Table 10 (page 55).
Memory subsystem behaviors
The processor and the integrated memory controller provides increased reliability of DIMMs. The
memory controller built into the 9300 series processor doubles memory rank error correction from
4 bytes to 8 bytes of a 128 byte cache line, during cache line misses initiated by processor cache
controllers and by DMA operations initiated by I/O devices. This feature is called double DRAM
sparing, since 2 of 72 DRAMs in any DIMM pair can fail without any loss of server performance.
Corrective action, such as DIMM/memory expander replacement, is required when a threshold is
reached for multiple double-byte errors from one or more DRAM chips in the same rank. All other
causes of memory DIMM errors are corrected by the processor and reported to the CMC and CPE
error logs / SID LED panel.
Customer messaging policy
The diagnostic LED illuminates only for memory DIMM errors when isolated to a specific DIMM.
If there is uncertainty about a specific DIMM, then the customer is pointed to the SEL for any
90 Troubleshooting