Conversion Guide - HP Integrity rx3600 Rack to Pedestal

Server Orientation
IMPORTANT: In this document the server top, bottom, right and left always refer to the server
as faced from the front with the server in a horizontal orientation. The pedestal kit components
are referred to by their final position with the server in a vertical orientation. For example, the
pedestal kit bottom attaches to the server left side.
Figure 2-1 Front of Server
1
1
2
2
3
3
4
4
1
Server Top / Pedestal Kit Left Side
2
Server Left / Pedestal Kit Bottom
3
Server Bottom / Pedestal Kit Right Side
4
Server Right / Pedestal Kit Top
Installing the Pedestal Kit Top and Bottom
The pedestal kit bottom attaches to the left side of the server. The pedestal kit top attaches to the
right side of the server. The pedestal bottom may be distinguished from the pedestal top by the
pedestal feet slots.
Follow these steps to attach the pedestal top and bottom.
1. Align the holes in the pedestal component with the rivets on the server.
NOTE: One of the holes in the pedestal component contains the locking mechanism. This
will make the hole appear partially blocked.
2. Hold the pedestal component flush against the server.
3. Slide the pedestal component forward until it locks into place
Installing the Bezel Cover
Follow these steps to install the bezel cover.
8 Rack to Pedestal Conversion