HP Integrity rx3600 Server User Service Guide
Processor Problem Identification
• A diagnostic LED only lights for physical CPU core errors, when a specific processor module
is isolated. If there is any uncertainty about a specific CPU the CRU LED on the diagnostic
panel is not lighted. Check the SEL for any errors or warnings.
• For physical configuration errors, for example, when there is no processor module installed
in CPU socket 0, all the CRU LEDs on the diagnostic LED panel light for all the missing processor
modules.
• No diagnostic messages are reported for single-bit errors that are corrected in both instruction
and data caches during corrected machine check (CMC) events to physical CPU core.
Diagnostic messages are reported for CMC events when thresholds are exceeded for single-bit
errors. Fatal processor errors cause global and local MCA events.
Table 52 and Table 53 list the processor events that light and that may light the diagnostic panel
LEDs.
Table 52 Processor Events that Light Diagnostic Panel LEDs
NotesSourceCauseIPMI EventDiagnostic
LEDs
This event follows
other failed
processors.
SFWThe processor failed and
was deconfigured.
Type E0h, 39d:04d
BOOT_DEConFIG_CPU
Processors
Threshold exceeded
for cache parity
WIN
Agent
Too many cache errors were
detected by the processor.
Type E0h, 5823d:26d
PFM_CACHE_ERR_PROC
Processors
errors on the
processor.
Threshold exceeded
for cache errors
WIN
Agent
Too many corrected errors
detected by the platform.
Type E0h, 5824d:26d
PFM_CORR_ERROR_MEM
Processors
from the processor,
corrected by Zx2.
Power Pod voltage
is out of range ( too
low).
BMCVoltage on the FRU is
inadequate.
Type 02h, 02h:07h:03h
VOLTAGE_DEGRADES_TO_Non_RECOVERABLE
Processors
Voltage on the FRU
is inadequate.
BMCVoltage on the FRU is
inadequate.
Type 02h, 02h:07h:03h
VOLTAGE_DEGRADES_TO_Non_RECOVERABLE
Processor
Carrier
Table 53 Processor Events That May Light Diagnostic Panel LEDs
NotesSourceCauseIPMI EventDiagnostic
LEDs
SFWInstalled processors are not
compatible.
Type E0h, 734d:26d
BOOT_CPU_LOADING_ERROR
Processors
SFWProcessors and/or
termination are out of order.
Type E0h, 2953d:26d
BOOT_CPU_LOADING_ERROR
Processors
SFWA logical CPU thread failed
a late self test.
Type E0h, 36d:26d
BOOT_CPU_LATE_TEST_FAIL
Processors
SFWA logical CPU thread slave
failed to rendezvous.
Type E0h, 677d:26d
MC_RENDEZVOUS_SLAVES_FAIL
Processors
SFWA CPU core failed the
configuration process.
Type E0h, 30d:26d
BOOT_CPU_ConFIG_FAIL
Processors
SFWA processor’s fixed core
frequency ratio is
Type E0h, 790d:26d
BOOT_CPU_BAD_CORE_FIXED_RATIO
Processor
incompatible with the bus
frequency.
CPU, Memory and SBA 143