HP Integrity rx3600 Server User Service Guide
Table 55 Memory Subsystem Events that May Light Diagnostic Panel LEDs (continued)
NotesSourceCauseIPMI EventsDiagnostic
LEDs
SFWThe CEC failed the
register test.
Type E0h, 160d:26d
MEM_BIB_REG_FAILURE
Processor
Carrier
SFWSystem firmware (SFW)
was unable to clear the
Type E0h, 187d:26d
MEM_ECC_MBE_SIGNAL_TST_FAILED
Processor
Carrier
platform error logs on the
CEC.
SFWThe error registers in the
CEC failed to clear.
Type E0h, 190d:26d
MEM_ERR_REG_CLEAR_FAILURE
Processor
Carrier
SFWThe CEC memory
controller failed the
register test.
Type E0h, 208d:26d
MEM_MC_REG_FAILURE
Processor
Carrier
Voltage wholly
contained on the
BMCMemory card voltage
error.
Type 02h, 02h:07h:06h
VOLTAGE_Non_RECOVERABLE
Memory
Carrier
memory carrier has
failed.
The failing DIMM
quad will be
deallocated.
SFWAn SDRAM is failing on
the DIMM.
Type E0h, 4000d:26d
MEM_CHIPSPARE_DEALLOC_RANK
DIMMs
SFWDIMM type is not
compatible with current
DIMMs.
Type E0h, 174d:26d
MEM_DIMM_TYPE_INCOMPATIBLE
DIMMs
SFWDetected a fatal error in
the DIMM serial presence
detect (SPD).
Type E0h, 173d:26d
MEM_DIMM_SPD_FATAL
DIMMs
24 or 48 slot memory
carrier.
SFWDIMM mismatch was
found within a quad of
DIMMs.
Type E0h, 795d:26d
MEM_DIMM_QUAD_MISMATCH
DIMMs
8 slot memory carrier.SFWDIMM mismatch was
found within a pair of
DIMMs.
Type E0h, 779d:26d
MEM_DIMM_PAIR_MISMATCH
DIMMs
Figure 49 shows the DIMM slot IDs for the 8-DIMM memory carrier board.
146 Troubleshooting