HP Integrity rx3600 Server User Service Guide

Hot-Swappable Components
A component is defined as hot-swappable if you can remove it from the chassis while the server
remains operational. Hot-swappable components require no software intervention prior to removing
the component.
NOTE: Hot-swappable components are marked with red touch points.
The following are hot-swappable components:
Fan units
Power supplies
Disk drive fillers
Hot-Pluggable Components
A component is defined as hot-pluggable if you can remove it from the chassis while the server
remains operational. Software intervention is required prior to removing a hot-pluggable component.
NOTE: Hot-pluggable components are marked with red touch points.
The following are hot-pluggable components:
Disk drives
PCI/PCI-X/PCIe cards
Cold-Swappable Components
To remove and replace cold-swappable components, or components that are neither hot-swappable
nor hot-pluggable, shut down the operating system and power off the server. For complete
instructions on shutting down the operating system and powering off the server, see Chapter 4
(page 108).
NOTE: Cold-swappable components are marked with blue touch points.
The following are cold-swappable components:
Front bezel
DVD drive
Memory carrier assembly
Memory DIMMs
Processor board assembly
Dual-core processors
I/O board assembly
System battery
I/O voltage regulator module
Trusted Platform Module
PCI/PCI-X card divider
Core I/O board
Core I/O board battery
SAS core I/O card
LAN core I/O card
HP Integrity rx3600 Component Classification 163