HP Integrity rx3600 Server User Service Guide

Table 72 PCI/PCI-X/PCIe I/O Paths (continued)
EFI Device PathHP-UX Device
Path
Location as
viewed from
rear of chassis
Function
Associated with
Path
Slot
Acpi(HWP0002,PNP0A03,0)/Pci(2|*)0/0/2/*Right most
special slot
Core I/O USBCore
I/O
board
Acpi(HWP0002,PNP0A03,0)/Pci(4|*)0/0/4/*Right most
special slot
Core I/O VGA
(optional)
Core
I/O
board
1
The Core I/O LAN may be in slot 10 depending upon the configuration.
2
IMPORTANT: The new version of the PCI/PCI-X/PCIe backplane (version 1.1) is being shipped on July 1, 2008. For
existing servers, repair and replace should continue to be performed with the version 1 I/O backplane. For servers
shipped as of July 1, 2008, repair and replace should be performed with version 1.1 I/O backplane. The device paths
for version 1.1 are as follows.
EFI Device PathHP-UX Device Path
Location as Viewed from
Rear of Chassis
Function Associated
with PathSlot
Acpi(HPQ0002,PNP0A08,600)/Pci(0|
0)/Pci(0|0)/Pci(1|0)/Pci(0|*)
0/6/0/0/0/0/1/0/03rd from leftI/O PCIe x8
(switched with slot 4)
Optional SAS core
I/O card
3
Acpi(HPQ0002,PNP0A08,600)/Pci(0|
0)/Pci(0|0)/Pci(0|0)/Pci(0|*)
0/6/0/0/0/0/0/0/04rd from leftI/O PCIe x8
(switched with slot 3)
Optional SAS core
I/O card
4
Online Addition (OLA)
IMPORTANT: Before installing a PCI/PCI-X/PCIe card, ensure you install the proper drivers.
To add a PCI/PCI-X/PCIe card into an empty slot, follow these steps:
1. If rack installed, slide the server completely out from the rack. See “Extending the Server from
the Rack” (page 164).
2. Remove the top cover from the chassis. See “Removing the Top Cover” (page 45).
3. Select an empty slot that is appropriate for the card you are installing. See “PCI/PCI-X
Configurations” (page 177) for more information.
CAUTION: Do not accidentally push the MRL of a powered-on, occupied slot; this
automatically cuts off the power for that slot.
4. Open the MRL.
a. Press the indentation on the MRL to release it from the chassis wall.
b. Lift the edge of the MRL, and rotate it upward 90 degrees until it rests against the chassis
wall and the PCI/PCI-X card bulkhead filler is fully exposed.
Removing and Replacing a Hot-Pluggable PCI/PCI-X/PCIe Card 181