HP Integrity rx3600 Server User Service Guide

4. Pull the gate latch toward the front of the chassis to completely unlock the PCI/PCI-X/PCIe
card if it is full-length.
5. Open the MRL.
a. Press the indentation on the MRL to release it from the chassis wall.
b. Lift the edge of the MRL, and rotate it upward 90 degrees until it rests against the chassis
wall and the PCI/PCI-X/PCIe card bulkhead is fully exposed.
6. Disconnect all external and internal cables attached to the PCI/PCI-X/PCIe card.
7. Grasp the PCI/PCI-X/PCIe card divider by the handle, and pull upward to eject the
PCI/PCI-X/PCIe card from the slot.
8. Grasp the PCI/PCI-X/PCIe card by the edges and lift it out of the chassis.
Installing a PCI/PCI-X/PCIe Card Offline
NOTE: Before installing a PCI/PCI-X/PCIe card, ensure that you install the proper drivers for the
PCI/PCI-X/PCIe card.
To install a PCI/PCI-X/PCIe card with the server power off, follow these steps:
1. Power off the server and disconnect the power cables. See “Powering Off the Server
(page 82).
2. If rack installed, slide the server completely out from the rack. See “Extending the Server from
the Rack” (page 164).
3. Remove the top cover from the chassis. See “Removing the Top Cover” (page 165).
4. Select an empty slot that is appropriate for the card you are installing. For more information
see “PCI/PCI-X Configurations” (page 177) and Figure 60.
5. Open the MRL.
a. Press the indentation on the MRL to release it from the chassis wall.
b. Lift the edge of the MRL, and rotate it upward 90 degrees until it rests against the chassis
wall and the PCI/PCI-X/PCIe card bulkhead filler is fully exposed.
6. Remove the PCI/PCI-X/PCIe bulkhead filler.
7. Insert the PCI/PCI-X/PCIe card into the empty slot, and use firm, even pressure to seat the
card in the slot.
CAUTION: Ensure that you fully seat the card into the slot, or the card can fail after power
is reapplied to the slot.
8. Connect all internal and external cables to the PCI/PCI-X/PCIe card.
9. Close the MRL.
a. Rotate the MRL downward 90 degrees.
b. Push the edge of the MRL down until it clicks into place on the PCI/PCI-X/PCIe card
bulkhead.
10. Close the gate latch to secure the end of the card if it is full-length.
11. Replace the top cover. See “Replacing the Top Cover” (page 166).
12. If rack installed, slide the server completely into the rack. See “Inserting the Server into the
Rack” (page 164).
13. Reconnect the power cables and power on the server. See “Powering On the Server (page 81).
184 Removing and Replacing Server Components