Windows Integrity Management Agents Reference
Event DescriptionEvent SeverityEvent ID
EFI USB HCD interrupt service has detected the host controller is hung Probable
Cause: Problem with USB controller. Recommended Action: Reset the card containing
the USB interface to restart the controller.Contact your HP representative to check
the USB interface. SNMP Trap: hpevtEfiHcdHostHung - 5714 in HPIFPTRAP.MIB.Error5714
The EFI/SAL handoff structure's version does not match EFI expectations Probable
Cause: EFI/SAL firmware mismatch. Recommended Action: Reboot. If problem
persists contact your HP representative for support. SNMP Trap:
hpevtEfiSalHandoffVerMismatch - 5715 in HPIFPTRAP.MIB.Error5715
Unable to obtain access to all RTC SAL services Probable Cause: Not all expected
services are available. Mismatch between EFI and SAL versions. Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. SNMP Trap: hpevtEfiSalRtcServiceNotInit - 5717 in HPIFPTRAP.MIB.Error5717
Unable to obtain access to all SAL timer services Probable Cause: Not all expected
services are available. Mismatch between EFI and SAL versions. Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. SNMP Trap: hpevtEfiSalTimerServiceNotInit - 5718 in HPIFPTRAP.MIB.Error5718
EFI unable to start the periodic timer Probable Cause: Internal system firmware error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. SNMP Trap: hpevtEfiSalStarttimerServiceNotInit - 5719 in
HPIFPTRAP.MIB.Error5719
No I/O port space region found in the MDT Probable Cause: EFI/SAL handoff
structure corrupted. Recommended Action: Reboot. If problem persists contact your
HP representative for support. SNMP Trap: hpevtEfiNoIoPortSpaceRegionFound -
5720 in HPIFPTRAP.MIB.Error5720
EFI reached an unimplemented section of code Probable Cause: Reached
unimplemented firmware. Recommended Action: Upgrade system firmware. SNMP
Trap: hpevtEfiBreakpoint - 5721 in HPIFPTRAP.MIB.Error5721
EFI unable to read current speedy boot settings Probable Cause: BMC not functioning
properly. Recommended Action: Reset the BMC.Contact your HP representative to
check the BMC. SNMP Trap: hpevtEfiSpeedyBootTokenNotRead - 5722 in
HPIFPTRAP.MIB.Warning5722
Unpermitted SAL callback attempted Probable Cause: Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. SNMP Trap: hpevtEfiSalCallbackAttempted - 5723 in HPIFPTRAP.MIB.Error5723
EFI unable to determine frequency base of the CPU interval timer Probable Cause:
Invalid timer ratio. Recommended Action: Reset system. SNMP Trap:
hpevtEfiSalFreqBaseUnknown - 5724 in HPIFPTRAP.MIB.Warning5724
EFI system events already initialized Probable Cause: Multiple attempts to initialize
system events, EFI internal error. Recommended Action: Upgrade system firmware.
If problem persists, contact HP support to troubleshoot the problem. SNMP Trap:
hpevtEfiSysEventAlreadyInit - 5725 in HPIFPTRAP.MIB.Warning5725
Unable to create internal virtualization event while initializing IPMI events Probable
Cause: Out of resources. Internal EFI error. Recommended Action: Reboot
system.Upgrade system firmware. SNMP Trap: hpevtEfiSysEventCreateEventFail -
5726 in HPIFPTRAP.MIB.Warning5726
There was an error creating or initializing the FPGA node in firmware Probable
Cause: Unable to properly initialize a system firmware node Recommended Action:
Check for other errors in the system first. Invalidate NVM and retry to boot. Get the
latest firmware release. SNMP Trap: hpevtFpgaNodeInitError - 5728 in
HPIFPTRAP.MIB.Error5728
Error creating the pdh ioconfig node or attaching the service to it. Probable Cause:
This is likely to be a symptom of an earlier problem, or the system is out of malloc
space. Recommended Action: Contact system firmware team. SNMP Trap:
hpevtIoconfigNodeInitError - 5729 in HPIFPTRAP.MIB.Error5729
32 Management Agents Event Tables